Descargar Imprimir esta página

Stryker WiSe Guia Del Usuario página 40

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 203
Guidance and Manufacturer's Declaration: Electromagnetic Immunity
The WiSe™ 26" HDTV Surgical Display and WiSe™ HDTV Transmitter are intended for use
Display and WiSe™ HDTV Transmitter should ensure that they are used in such an environment.
Immunity Test
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects, and people.
(a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast,
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured
field strength in the location in which the WiSe™ 26" HDTV Surgical Display is used exceeds the
applicable RF compliance level above, the display and transmitter should be observed to verify
normal operation. If abnormal performance is observed, additional measures may be necessary, such
as reorienting or relocating the WiSe™ 26" HDTV Surgical Display.
(b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
36
in the electromagnetic environment specified below.
The customer or the user of the WiSe™ 26" HDTV Surgical
IEC 60601 Test
level
3 Vrms
150 kHz to 80
MHz
3 V/m
80MHz to 2.5
GHz
Compliance
Level
Portable and mobile RF communications
equipment should be used no closer to
any part of the WiSe™ HDTV Transmitter
system, including its cables, than the
recommended separation distance
calculated from the equation applicable to
Recommended Separation Distance
3 V
d = 1.17√P
d = 1.17√P 80 MHz to 800 MHz
3 V/m
d = 2.33√P 800 MHz to 2.5 GHz
where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
Field strengths from fixed RF transmitters,
as determined by an electromagnetic
site survey (a), should be less than the
compliance level in each frequency
Interference may occur in the vicinity
of equipment marked with the following
Electromagnetic
Environment - guidance
the frequency of the transmitter.
distance in meters (m).
range(b).
symbol: