ANSMANN ALCS 2-24 A Instruccion De Operación página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
a convenient mains socket. If no battery is connected the green LED for
24 V will light. After connecting the battery, the charger switches auto-
matically to the right voltage and the charging procedure will start. The
red LED indicates charging. After charging the red charging LED swit-
ches off and the battery is provided with trickle charging. The battery is
now fully charged and ready for use.
WARNING
When charging lead acid cells, explosive gases can develop. Avoid open
fire and sparks.
TIP
Do not carry out any cleaning if the charger is plugged in. Only use a dry
cloth to clean the charger. Do not use the charger if the housing is da-
maged. Chargers that require repair must be sent to authorised service
agents or dealers.
CAUTION
Keep your charger in a dry place (indoor use only). Never try to open the
charger. Danger of fire and electric shock!
SPECIFICATION
Voltage of the battery
2 Volt
6 Volt
12 Volt
24 Volt
Deutsch |
English
Svenska | Italiano | Nederlands | Dansk | Slovenščina
End of charging voltage
2.3 V
6.9 V
13.8 V
27.6 V
| Français | Pусский | Español | Português
Čeština | Slovenský | Polski
Charging current
900 mA
700 mA
600 mA
300 mA

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

9164016

Tabla de contenido