9.3.1 Output Name
The output name field is a way for the user to enter a name for the output. The output
name will show as an event on the Avire Hub when triggered.
9.3.2 Output Mode
The output Mode allows the user to choose mode of which the output will operate.
There are 2 modes to choose from.
9.3.2.1 Output with Hold Time
The output can be driven for a period of time with a click of a button. The "Output
with Hold time" mode allows the user to drive the output for the time (in seconds)
entered in the "Output Hold Time" field. Once the Hold Time has been programmed to
Connex-02 and the "Toggle" button pressed, the output will be ON for the period of
the Hold Time only.
9.3.2.2 Output Normal State
Defines whether the normal state of the output is OPEN or CLOSE. OPEN represents a
potential difference between both terminals of the output, CLOSE represents a short
between both terminals of the output.
9.3.3 Output Normal State
Defines whether the normal state of the output is OPEN or CLOSE. OPEN represents a
potential difference between both terminals of the output, CLOSE represents a short
between both terminals of the output.
9.3.4 Output Status
A read only function that shows the current status of the output when the "Read
parameters" button is pressed. This is either OPEN or CLOSE.
9.3.5 Activate / Deactivate
This is the "Toggle" button that drives the output. The output will change state when
this button is clicked from OPEN to CLOSE or vice versa.
9.3.6 Output Hold Time
This field is used to add the time (in seconds) that the output is driven for when the
"Toggle" button is pressed whilst in "Output with Hold Time" mode.