Fan/Light Controls
Rated at 120 V~ 60 Hz
AY2-LFSQ: Fan: 1.5 A, Light: 300 W
TG2-LFSQ: Fan: 1.5 A, Light: 300 W
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other equip-
ment, do not use to control receptacles, fluorescent lighting fixtures, or
transformer-supplied appliances.
2. Controls require separate wires in the wallbox for fan and light.
3. For new installations, wire a test switch before installing the control.
4. Set multispeed fans to their highest setting before installing controls.
5. Use an AY2-LFSQ, S2-LFSQ, S2W-LFSQ or TG2-LFSQ control with a
ceiling paddle fan only. Use only one ceiling paddle fan per control.
6. Use an S2-LF only with fans marked "Suitable for use with solid-state
P/N 030-1050
fan-speed controls."
7. Do not wire an AY2-LFSQ, S2-LFSQ, S2W-LFSQ or TG2-LFSQ in circuit
with a GFCI breaker/receptacle.
8. Controls may feel warm to the touch during normal operation.
9. When no "grounding means" exist within the wallbox then the NEC
2008, Article 404.9 allows a dimmer without a grounding connection to
be installed as a replacement, as long as a plastic, noncombustible
wallplate is used. For this type of installation, cap or remove the green
ground wire on the dimmer and use an appropriate wallplate such as
Lutron's Claro
series wallplates.
®
10. Install in accordance with all national and local electrical codes.
11. Clean control with a soft damp cloth only. Do not use any chemical cleaners.
12. For indoor use only.
13. Controls must be mounted vertically. See stamp on control for
correct positioning.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections before
wiring (see below). Use pliers to bend each side section up and down until it
breaks off. S2-LF controls require reduction of their capacity. Refer to chart
below for maximum capacity. Other fan-speed controls (-LFSQ) do not require
capacity reduction.
Break
Side Sections
Model Number
Load
S2-LF
Fan/Light
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center . Please provide exact model number when calling.
1.800.523.9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1.610.282.3800
Fax +1.610.282.6311
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after
purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg,
PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE
COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE,
ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER
INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES ARIS-
ING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF
THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some
states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an
implied warranty may last, so the above limitations may not apply to you.
This product may be covered by one or more of the following U.S. patents: 5,191,971; 5,262,678; 5,359,231;
5,637,930; and corresponding foreign patents. Lutron is a registered trademark of Lutron Electronics Co., Inc. NEC
is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. © 2008 Lutron
Electronics Co., Inc.
Lutron Technical Support Center
S2-LF:
Fan: 2.5 A, Light: 300 W
Installation
S2-LFSQ:
Fan: 1.5 A, Light: 300 W
For installations involving more than one control in a wallbox, refer to
S2W-LFSQ: Fan: 1.5 A, Light: 300 W
Multi-Unit Installations before beginning.
1 1
2 2
®
3 3
Tag the wire that is connected to the
feed side of the switch (the side with
the break-off fin).
Do Not Remove
Outside Sections
Break-off fin
Inside Sections Are
Side Sections Are
Removed From Each
Removed From Both
Control
Sides Of Middle Control
No Sides
1 Side
2 Sides
Removed
Removed
Removed
2.5 A/300 W
2.1 A/250 W
1.7 A/200 W
4 4
Internet: www.lutron.com
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in China. 10/08 P/N 030-1050 Rev. A
1.800.523.9466
WARNING: Turn power OFF at circuit breaker or remove fuse.
Removing wallplate and switch.
• Remove wall plate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Warning: Before proceeding, verify
that power to the switch is OFF.
Otherwise, death or serious injury
could result.
Verify application. This dimmer mounts in a single-gang wallbox
and independently controls a ceiling paddle fan and a light with
each slider. Independent wire must be provided for the fan and
light in addition to the feed wire (Live).
To Light
To Fan
Tag
Feed (Live)
Disconnect switch wires.
Turn screws to loosen.
24 hrs / 7 days
www.lutron.com
Important Wiring Information
When making wire connections, follow the recommended strip lengths and
combinations for the supplied wire connectors. Note: Wire connectors
provided are suitable for copper wire only. For aluminum wire, consult
an electrician.
Small:
Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm
) wire.
2
Strip insulation 1/2 in (13 mm) for 16 AWG (1.0 mm
) or
2
18 AWG (0.75 mm
) wire.
2
Use to join one 14 AWG (1.5 mm
) supply wire with one
2
16 AWG (1.0 mm
) or 18 AWG (0.75 mm
) control wire.
2
2
Large:
Strip insulation 1/2 in (13 mm) for 10 AWG (6 mm
),
2
12 AWG (2.5 mm
), or 14 AWG (1.5 mm
)wire.
2
2
Strip insulation 5/8 in (16 mm) for 16 AWG
(1.0 mm
) or 18 AWG (0.75 mm
) wire.
2
2
Use to join one or two 12 AWG (2.5 mm
)or
2
14 AWG (1.5 mm
) supply wires with one
2
10 AWG (6 mm
), 12 AWG (2.5 mm
), 14 AWG
2
2
(1.5 mm
), 16 AWG (1.0 mm
), or 18 AWG
2
2
Small
(0.75 mm
) control wire.
2
Wire the control.
5 5
• Connect the green ground wire
on the control to the bare cop-
TAG
per or green ground wire in the
Yellow
wallbox.
• Connect the black wire on the
control to the tagged wallbox
wire removed from the switch
(feed wire from the circuit
breaker or fuse box).
• Connect the yellow wire on the
Red
control to the wire leading to the
Black
fan.
Ground
Green
• Connect the red wire on the con-
trol to the wire leading to the light.
Live
Black
Yellow
120 V~
60 Hz
Red*
Green
Fan
Light
Ground
*Cap off Red wire
Neutral
if no light is used.
6 6
Mount and align control. Install wallplate.
Start screws.
Align control and
tighten screws.
7 7
Turn power ON.
Twist wire connector tight.
Be sure no bare wire is
exposed.
Large