Fan / Light Controls
Rated at 120 V
60 Hz
AY2-LFSQ:
Fan: 1.5 A Light: 300 W
TG2-LFSQ:
Fan: 1.5 A Light: 300 W
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other equipment, do not use
to control receptacles, fluorescent lighting fixtures, or transformer-supplied appliances.
2. Controls require separate wires in the wallbox for fan and light.
3. For new installations, wire a test switch before installing the control.
4. Set multispeed fans to their highest setting before installing controls.
5. Use an AY2-LFSQ, S2-LFSQ, S2W-LFSQ or TG2-LFSQ control with a ceiling paddle fan
only. Use only one ceiling paddle fan per control.
P/N 030-1276
6. Use an S2-LF only with fans marked "Suitable for use with solid-state fan-speed controls."
7. Do not wire an AY2-LFSQ, S2-LFSQ, S2W-LFSQ or TG2-LFSQ in circuit with a GFCI
breaker/receptacle.
8. Controls may feel warm to the touch during normal operation.
9. When no "grounding means" exist within the wallbox then the NEC
allows a dimmer without a grounding connection to be installed as a replacement, as
long as a plastic, noncombustible wallplate is used. For this type of installation, cap or
remove the green ground wire on the dimmer and use an appropriate wallplate such as
Claro
series wallplates by Lutron
®
10. Install in accordance with all national and local electrical codes.
11. Clean control with a soft damp cloth only . Do not use any chemical cleaners.
Multi-Unit Installations
When combining controls in a wallbox, remove all inner side sections before wiring
(see below). Use pliers to bend each side section up and down until it breaks off. S2-LF
controls require reduction of their capacity. Refer to chart below for maximum capacity.
Other fan-speed controls (-LFSQ) do not require capacity reduction.
Break
Side Sections
Model Number
Load
S2-LF
Fan / Light
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center . Please provide exact model number when calling.
1.800.523.9466 (U.S.A., Canada, and the Caribbean)
+1.610.282.3800 (Other countries)
Fax +1.610.282.6311
Internet: www.lutron.com
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one
year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter
Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY
OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT
COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM
MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES
NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR
DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,
DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation
on how long an implied warranty may last, so the above limitations may not apply to you.
Lutron and Claro are a registered trademarks of Lutron Electronics Co., Inc. NEC is a registered
trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2010 Lutron Electronics Co., Inc.
English
Lutron Technical Support Center
S2-LF:
Fan: 2.5 A Light: 300 W
Installation
S2-LFSQ:
Fan: 1.5 A Light: 300 W
For installations involving more than one control in a wallbox, refer to Multi-Unit
S2W-LFSQ:
Fan: 1.5 A Light: 300 W
Installations before beginning.
1 1
2 2
2008, Article 404.9
®
.
®
3 3
Tag the wire that is connected to the feed side
of the switch (the side with the break-off fin).
Do Not Remove
Outside Sections
Break-off fin
Inside Sections Are
Side Sections Are Removed
From Both Sides Of Middle
Removed From Each
Control
Control
No Sides
1 Side
2 Sides
Removed
Removed
Removed
2.5 A 300 W
2.1 A 250 W
1.7 A 200 W
+1.888.235.2910 (México)
4 4
1.800.523.9466
WARNING: Turn power OFF at circuit breaker or remove fuse.
WARNING: Shock Hazard. May result in serious
injury or death. Turn of power at circuit breaker
before installing the unit.
Remove switch mounting screws. Pull switch from wall.
Verify application. This dimmer mounts in a single-gang wallbox and independently
controls a ceiling paddle fan and a light with each slider. Independent wire must
be provided for the fan and light in addition to the feed wire (Live).
To Light
To Fan
Tag
Feed (Live)
Disconnect switch wires.
Turn screws to loosen.
24 hrs / 7 days
www.lutron.com
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for copper
wire only. For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm
2
) wire.
Strip insulation 1/2 in (13 mm) for 16 or 18 AWG (1.0 or 0.75 mm
Use to join one 14 AWG (1.5 mm
2
) supply wire with one 16 or 18 AWG
(1.0 or 0.75 mm
2
) control wire.
Large:
Strip insulation 1/2 in (13 mm) for 10 to 14 AWG (6 to 1.5 mm
Strip insulation 5/8 in (16 mm) for 16 or 18 AWG
(1.0 or 0.75 mm
2
) wire.
Use to join one or two 12 or 14 AWG (2.5 or 1.5 mm
2
)
supply wires with one 10 to 18 AWG (6 to 0.75 mm
2
)
control wire.
Wire the control.
5 5
• Connect the green ground
wire on the control to the bare copper
TAG
or green ground wire in the wallbox.
Yellow
• Connect the black wire on the control
to the tagged wallbox wire removed
from the switch (feed wire from the
circuit breaker or fuse box).
• Connect the yellow wire on
the control to the wire leading
Red
to the fan.
Black
• Connect the red wire on the control to
Ground
Green
the wire leading to the light.
Live
Black
Yellow
120 V~
60 Hz
Red*
Green
Fan
Light
Ground
*Cap of Red wire if
Neutral
no light is used.
6 6
Mount and align control. Install wallplate.
Start screws.
7 7
Turn power ON.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A. 3/10 P/N 030-1276 Rev. B
Twist wire
connector tight.
Be sure no bare
2
) wire.
wire is exposed.
) wire.
2
Large
Small
Align control and
tighten screws.