Fault
Appliance does not become cold,
indicator light does not come on.
Appliance does not become cold,
indicator light comes on.
Appliance becomes cold,
indicator light does not come on.
Increased formation of bloom and
ice; reduced efficiency or lower
cooling power.
Stacker "pulls" to left or right dur-
ing transport.
Resistance to rolling of the
wheels higher than when put into
operation.
The total locks no longer have
any locking action.
Platform no longer rises even with
a low load.
Regular inspection and maintenance of the appliance prevent disruptions to operation and ensure safety.
Inspection and maintenance intervals depend upon the use of the appliance. Consult your dealer's after-sales
service department.
28
Coolstapler - basket stacker with cooling by circulating air
Possible cause
Defective fuse at the building
end.
ON/OFF switch defective.
Mains connection cable or
mains plug defective.
Cooling assembly defective.
Refrigerant circuit leaky.
Indicator light defective.
Introduction of foods which
are still warm or not covered
and give off moisture.
Ambient air too warm.
Damaged roller bearing(s).
Wear of the locking brake
due to continual misuse as
travel brake.
Breakage of a spring.
Action
Check fuse and repair if need be.
Disconnect appliance from the mains
and have it checked and repaired if
need be by authorised specialist staff.
Disconnect appliance from the mains
and have it checked and repaired if
need be by authorised specialist staff.
Disconnect appliance from the mains
and have it checked and repaired if
need be by authorised specialist staff.
Disconnect appliance from power sup-
ply, leave to return to the right tempera-
ture and clean with warm damp cloth.
Please note: only precooled foods
should be introduced and all foods
must be covered.
Please observe the permitted ambient
temperatures: +10 to +32 °C.
Replace defective rollers with new
ones.
Either renew the locking brake or
replace the defective roller(s) with new
one(s).
Replace spring with new.