AUXILIARY CONTACT CONFIGURATION
The auxiliary contact can be configured for various uses by simply
pressing key R for 5 seconds. The move between the various modes is
confirmed by red blinks from the left-hand LED.
The signal is also given in the case where the reset functions are
deactivated to prevent accidental deactivation.
• Status 1 (default): operation with light indicator.
On locking the NO contact switches and remains closed until a reset is
operated.
Pressing R
for 5 seconds
• Status 2: communication with the telephone dialler
Activation confirmed by 2 blinks. On wait or block the NC contact switches
and remains open until an eventual reset.
• Status 3: operation with bell.
Activation confirmed by 2 blinks. On locking the NO contact switches to
intermittance at a frequency of 1 Hz for 30 seconds and repeats the
sequence every hour.
Pressing R
for 5 seconds
Press R for 5 seconds to return to Status 1. Activation confirmed by 1 blink.
23
Telephone
dialler
Bell
E
N
G
L
I
S
H