Electrical Connections - Craftmade Artistry AY56 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

15
Setting Frequency Switches
The remote control unit is operated by a set of frequency switches and are
preset at the factory. The switches are located on the back of the remote
control unit and in the top motor housing of the fan on the receiving
module. The switches can be set in any position as long as both the wall
unit and receiving module switches are set the same. All (RF) modules &
Transmitters come from the factory with the dip switches set in the (ON)
position.
To replace battery, simply push down on tab and slide housing cover off.
Snap 9-Volt battery onto wire terminal and replace into remote housing.
Slide housing cover back onto remote control unit.
1 2 3 4
ON
All manuals and user guides at all-guides.com
Remote
Control Unit
1 2 3 4
ON
Battery
Terminal
PUSH
Housing
Cover
Remote
Housing
16

Electrical Connections

Connect black fan wires to black outlet wire. Connect white fan wire to
white outlet wire and green grounding lead wire from the grounding
conductor to the supply circuit (see figure A). Use wire connectors
provided with your fan. No loose strands or loose connections should be
present. Turn splices upward and carefully push all wiring into outlet box.
When wall switches are employed, switches should be UL listed for use
with ceiling fan.
CAUTION: Always turn off power at breaker before attempting any wire
connections.
Black
Fan and lights
controlled by
remote control
unit
Ground
White
Black
Black
Light Switch
Blue
Figure B
Ground
White
Blue
Black
Figure A
Green
White
Green
White

Publicidad

Tabla de contenido
loading

Tabla de contenido