DAILY MAINTENANCE

1.
Use the attached drain hose to empty the dirty
water from the recovery tank. (See Figure 14)
Figure 14
2. Remove lid and check that dirty water tank float is
undamaged, clean and moves freely on pin.
(See Figures 15 and 16)
Figure 15
3. Lift off recovery tank to clean. (See Figure 17)
Figure 17
4. Clean brush and check squeegee is clean and
blades are not damaged. (See Figure 18)
Figure 18
PAGE 4 OF 21
MAINTENANCE
Figure 16
5. Check battery charge. (See Figure 19)
Figure 19
6. To recharge batteries, plug in battery charger using
electrical cord provided with machine. Charge is
complete when the green LED light is on.
(See Figures 20 and 21)
Figure 20
REPLACING THE SQUEEGEE BLADE
1.
Remove the squeegee assembly using the two
black knobs.
2. Remove the squeegee
blade by removing the
screws, wing nuts and
blade retainers.
(See Figure 22)
3. Reuse the same blade
by reversing the edge
in contact with the floor.
The blades should be
reused until all four
edges are worn out and can be replaced at once.
4. Align the new (or reversed) blades with the tabs and
screw holes on the squeegee body.
5. Reposition the two blade retainers, and insert the
screws. Attach and tighten the wing nuts.

BRUSH REPLACEMENT

1.
With the underside exposed, remove brush by
rotating clockwise off the center hub.
2. Install new brush by rotating counterclockwise onto
the center hub.
Figure 21
Blade
Retainer
Figure 22