Monitoring By Cycle Switch - Vogel KFG Serie Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 138

7.6 Monitoring by cycle switch

Possible only for centralized lubrication
systems with progressively-acting
distributors.
For greases up to NLGI Class 2.
The cycle switch monitors the movement of the
pistons in the progressively-acting distributor during
the CONTACT time.
In the programming mode, the following monitoring
feature must be activated: COP = CS
7
black
7
Fig. 15 Electrical connection of cycle switch
Page 33
Contents
Operating Instructions KFG, KFGS
2
6
8
2
1
1 set KFGS1-5
2 lubrication line
3 main distributor
4 sub-distributor
5 friction points
6 cycle switch
7 electric compartment
8 excess pressure valve
Chapter
7
4
2
3
5

Publicidad

Tabla de contenido
loading

Productos relacionados para Vogel KFG Serie

Este manual también es adecuado para:

Kfgs serieKfgs 1-5Kfgs 3-5Kfgs 5-5