Master TERA Manual De Uso Y Mantenimiento página 15

Motores tubulares 45 mm con final de carrera electronico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

12. RESET
WARNING: This procedure restores the factory settings of the device. This procedure must be carried out by qualified technical personnel. Once the "reset" is
performed, the technician must install this device again (following the procedure on section 06) and verify proper operation.
12.1 USING A TRANSMITTER
ARCO
01. Bring the motor in an intermediate position.
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 2 time PREV / 9 times NEXT.
«29» appears on display
04. Press STOP. The display flashes, the
motor performs some movement
05. Press together PREV and NEXT for about
2 seconds until the motor indicates that the
reset was performed (1 moving up / down).
06. Reinstall the motor (see section 6).
12.2 USING COMMAND BUTTONS
01. If possible, bring the motor to the intermediate position.
02. Disconnect the power supply.
03. Connect as on the diagram.
04. Connect the power supply. Wait 30 seconds, the motor makes a signal: «Reset done».
05. Disconnect the power supply.
06. Restore the connections (see diagram on section 5).
07. Reinstall the motor (see section 6).
13. COMPATIBILITY WITH RADIO SENSORS
This motor is compatible with the X11C radio rain sensor associated with the AT12 power supply.
This motor can not be associated with radio wind sensors and radio wind / sun sensors.
14. OPERATING LOGIC OF COMMAND BUTTONS
The buttons can be operated either in PULSE logic or HOLD-TO-RUN logic.
PULSE: to activate the motor press a button for at least 0.5 seconds, to stop the motor press briefly (less than 0.5
seconds) one of the two buttons.
HOLD-TO-RUN: to activate the motor press a button for at least 0.5 seconds, to stop the motor release the button.
The factory sets the device to work in PULSE logic.
WARNING: when you are executing an hold-to-run command and a radio command intervenes, the motor stops a
hold-to-run command and executes the new maneuver: the radio command has priority.
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 1 time PREV / 8 times NEXT.
«18» appears on display
04. Press STOP. The motor signals:
see table
05. To select PULSE: press PREV
To select HOLD-TO-RUN: press NEXT
06. Press STOP. The motor signals:
see table
Interfacing with Home Automation Control Unit
14.1
The control outputs of the Home Automation Control Unit (following H.A.C.U.) must be connected to the command inputs of the motor (GRAY and BLACK wires), replacing the manual
buttons. Consequently, the H.A.C.U. must comply with the rules of operation of the command buttons, depending on whether the command buttons work in PULSE mode (factory
setting) or in HOLD TO RUN mode (see section 14 " Operating logic of command buttons").
Rules that the H.A.C.U. must comply to control the device operating with buttons in PULSE mode.
a) The H.A.C.U. must not measure the current drawn by the command inputs of the device (which absorb less than 1 mA).
b) The H.A.C.U. must be connected to the device as shown, substituting the command buttons with the outputs of the H.A.C.U..
c) To operate the motor, the H.A.C.U. must close contact (up or down) for more than 0.5 seconds (typically using a pulse duration of 1 second).
d) To stop the motor, the H.A.C.U. must close contact (up or down) for 0.5 seconds or less (typically using a pulse duration of 0.2 seconds).
Rules that the H.A.C.U. must comply to control the device operating with buttons in HOLD TO RUN mode.
a) The H.A.C.U. must not measure the current drawn by the command inputs of the device (which absorb less than 1 mA).
b) The H.A.C.U. must be connected to the device as shown, substituting the command buttons with the outputs of the H.A.C.U..
c) To allow the conclusion of the entire opening / closing, the H.A.C.U. must be able to close the contact UP / DOWN to the time required for the motor to perform the complete
operation.
d) To stop the motor, the H.A.C.U. must be able to re-open the contacts UP / DOWN at any time.
At the time of this document printing, specific issues related to the connection between MASTER products and H.A.C.U. are not known (if you follow the rules above). However
MASTER disclaims any responsibility concerning the non-compatibility (even partial) with any H.A.C.U.. If the H.A.C.U. uses KNX protocols or similar, contact the vendors of home
automation controller informing them of the rules above. Probably the manufacturer of H.A.C.U. can provide appropriate interfaces to connect the device to the H.A.C.U..
FLUTE, KUADRO, KORT
01. Bring the motor in an intermediate position.
02. Holding down STOP, press PROG for
about 1 sec, until LEDs light
03. Press 2 time UP / 9 times DOWN.
04. Press STOP. The LEDs flash, the motor
performs some movement
05. Press together UP and DOWN for about 2
seconds until the motor indicates that the
reset was performed (1 moving up /
down).
06. Reinstall the motor (see section 6).
FLUTE, KUADRO, KORT
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for
about 1 sec, until LEDs light
03. Press 1 time UP / 8 times DOWN.
04. Press STOP. The motor signals:
see table
05. To select PULSE: press DOWN
To select HOLD-TO-RUN: press UP
06. Press STOP. The motor signals:
see table
VISIO
01. Bring the motor in an intermediate position.
02. Press MENU, «Menu rx» appears on
display
03. Press 2 time PREV / 9 times NEXT.
«29» appears on display
04. Press STOP. The display flashes, the
motor performs some movement
05. Press together PREV and NEXT for about
2 seconds until the motor indicates that
the reset was performed (1 moving up /
down).
06. Reinstall the motor (see section 6).
5 poles
cable
Number of movements
* factory setting
VISIO
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 1 time PREV / 8 times NEXT.
«18» appears on display
04. Press STOP. The motor signals:
see table
05. To select PULSE: press DOWN
To select HOLD-TO-RUN: press UP
06. Press STOP. The motor signals:
see table
07
Other transmitters...
See the User manual of
the transmitter at
«RECEIVER MENU -
Function 29 -
Receiver reset»
gray
black
brown
blue
yellow/green
Setting
*
Pulse
1
2
Hold-to-run
Other transmitters...
See the User manual of
the transmitter at
«RECEIVER MENU -
Function 18 -
Buttons logic»
section:
section:

Publicidad

Tabla de contenido
loading

Tabla de contenido