Installation instructions 20408_15_22 // 20508_15_22
1.
Ceiling and luminaire connection
(Step 1)
Step 1. Take out the 3 side screw of the bracket.
Step 2. Fix the bracket into the ceiling or wall, connect the wire to power source.
Step 3. Fix the light to the bracket then turn right the screws to lock them.
(3)=3000K; (4)=4000K
REFERENCE
POWER (W)
20408
8
20415
15
20422
22
20508
8
20515
15
20522
22
Note 1: The IP value refers to the external value. The internal IP index of the products are 20. Additional information can be checked in the product data sheet.
The connection block is not supplied with the luminaire.
The authorized electrician will have to make the electrical connection by using a connection block, with two screws with phase + neutral,
1,5mm2/10A/250V capacity and IP degree adecuated to the luminaire marking, which meets EN 60998, or, if it is possibledue to the driver features,
directly to the driver with wiring (Blue=N and Brown=L) class II adecuate in order to maintain the the isolation class.
Warnings
- Please, read and keep, in safe place, the installation instructions before starting the installation af the product.
- Cut the main power supply before starting the installation works.
- If the luminaire connections are damaged, the replacement must be done by JISO ILUMINACIÓN, SL. or by an authorized electrican with the aproval
of JISO ILUMINACIÓN, SL.
- The light source of this luminaire is NOT REMOVABLE, when the light source reaches the end of its life, the complete lamp must be replaced.
- The installation must be carried out by qualified personnel.
- Improper handling of the components or the luminaire itself could damage the correct functioning of this product, thus voiding the manufacturer's
warranty.
- Luminaire suitable only to be used indoor.
- JISO ILUMINACIÓN is not responsible for the improper use or modifications made to the product.
- The luminaire must not be covered by insulating material or similar under any circumstances.
- DO NOT touch the luminaire when it is on or until a reasonable time has elapsed after it has been switched off.
- DO NOT use aggressive material (solvent type or similar) to clean the luminaire. The surface may be damaged.
- The luminaire is designed to be used, only, connected to a stable power supply network. 220-240 ~ 50 / 60Hz.
JISO ILUMINACIÓN, S.L. reserves the right to make technical, formal and dimensional modifications at any time and without prior notice. It is not allow
to reproduce totally or parcially this document without authorization from JISO ILUMINACIÓN, SL.
JISO ILUMINACIÓN assumes no responsibility for any errors that may appear in this document.
Do not eliminate with domestic wastes
Company adhered to ECOEMBES.
Cumplimiento directiva 2002/95/CE de Restricción de ciertas
Sustances in electrical and electronic equipment.
Indicates the compliance with low voltage diretives.
Check updated information on our website:
www.jisoiluminacion.com
(Step 2)
LÚMENS (lm)
OPENING
415 (3)/434 (4)
120º
887 (3)/949 (4)
120º
1518 (3)/1597 (4)
120º
455 (3)/476 (4)
120º
937 (3)/969 (4)
120º
1692 (3)1773 (4)
120º
(Figure 2)
(Step 3)
IP DEGREE
DIMENSIONS (mm)
33
120*120*H35
33
180*180*H35
33
220*220*H35
33
Ø120*H35
33
Ø180*H35
33
Ø220*H35
Class II Protection. Double insulation
Color rendering index.
Energy efficiency within A and A++.
Luminaire to be used indoor.
Surface assembly. Light to be installed on NOT
combustible/inflammble surfaces only. EN 60598-1:2008.
CUT (mm)
----
----
----
----
----
----