Stud Layout Setting
You can define a set measurement to use when
doing equidistant layouts. For example, if you need
to layout studs at 24cm apart, you can define this
distance from the Settings menu F3.
Once you have defined the distance:
1. Select the Dynamic Measuring mode.
2. Position the laser at the beginning of your layout line.
3. From the starting point, move the laser along a straight line.
When you get close to the defined distance, the laser displays
arrows to help you find the exact point and beeps when you are
aligned.
Laser Pointer Mode
You can activate the laser pointer from the Set-
tings menu F4.
Press
or
Maintenance
• Clean the aperture lens and the Laser Distance Measurer
body using a clean soft cloth only. Do not use solvents.
• If the Distancemeter is exposed to water, dry it before storing.
• Remove the battery if the laser measurer will be unused for
a long period of time.
18
to turn the laser on and off.