of 240 min. per eight hours, is 78 dB(A), according
to ED 86/188/EEC and ED 200311 0/EEC.
Therefore during he appliance's normal operation,
no pro-visions are to be taken in order to prevent
such risks arising or likely to arise from noise expo-
sure at work (articles 3-8 of ED 2003/10/EEC).
Maintenance
It is essential to check the state of the supply cable
and plug periodically.
IN THE EVENT THE SUPPLY CABLE OR PLUG ARE
DAMAGED, CALL IN SKILLED TECHNICAL PERSON-
NEL TO REPLACE THEM, THIS TO PREVENT ANY
RISK. IN CE-CERTIFIED APPLIANCES A SPECIAL
TOOL IS REQUIRED TO OPEN THE BASE PLATE TO
GET AT THE CABLE.
It is recommended to use original spare parts only.
In order to assure the lasting efficiency of the appli-
ance, skilled technical personnel must be called in
to perform periodical maintenance, including
detailed checks of the state of those components
subject to wear.
The state of the grinding blades must be checked
periodically. Keeping the grinding blades in an
excellent state assures high-quality grinding, result-
ing in greater productivity and limited overheating.
Cleaning the appliance
DISCONNECT THE APPLIANCE'S POWER SUPPLY
BY UNPLUGGING IT BEFORE CLEANING.
THE APPLIANCE MUST NOT BE CLEANED USING
WATER JETS.
Do not install the appliance in rooms where water
jets are used for cleaning.
THE APPLIANCE MUST BE CLEANED PERIODICALLY
BY SKILLED TECHNICAL PERSONNEL ONLY.
Use perfectly clean, disinfected cloths or brushes for
cleaning.
Do not use abrasive products as these are liable to
take the sheen off shiny parts.
Hopper
Wash the hopper once it has been removed from
the appliance (unscrewing the relevant fastening
screw), using neutral soap and water, rinse abun-
dantly with lukewarm water and dry thoroughly.
It is advisable to clean the hopper periodically.
Once the hopper has been cleaned, it must be
attached to the upper grinding blade holder using
the relevant screw.
Grinding system
Remove the safety screw which prevents the adjust-
ment disk from being removed. Unscrew the
adjustment disk by turning it clockwise. Having
removed the upper grinding blade holder, clean the
grinding blades, threads and the entire grinding sys-
tem thoroughly using a clean brush and cloth.
Having refitted the upper grinding blade holder in
the relevant slot, screw the adjustment disk back
on, put the self-locking screw back in whichever of
the two holes on the disk enables the best adjust-
ment and, having refitted the hopper and secured,
adjust the grinding as required.
Statistics display
It is possible to hide the statistics that can be
scrolled through when the grinder/doser is in
standby:
Enter the factory-set settings then scroll to SHOW
STATISTICS, with the P1 and P2 buttons select NO
to hide the statistics.
STATISTICS
Once NO is set in the Statistics Display, the opera-
tor can see only the date, time and day.
NB: The authorized engineer can display the statis-
tics by pressing the P1 and P2 buttons simultane-
ously; P1, P2 and P3 will flash constantly and the
statistics shall be displayed till the engineer touches
any button and return to the standby menu.
20
SHOW
YES