New Cartridge Conditioning
Carbon Filter
Hollow Fiber
Cartridge
Cartridge
(Blue Label)
(Green Label)
3. Condition New Cartridges
Install the hollow fiber cartridge (green label) in the left cartridge
position.
Install the carbon filter cartridge (blue label) in the right cartridge
position.
Turn on the cold water supply and check all connections for
leaks.
Run water through the faucet for 10 minutes to remove any air
and carbon particles from the system.
Turn off the water.
Remove both cartridges.
Install the carbon filter cartridge (blue label) in the left cartridge
position.
Install the hollow fiber cartridge (green label) in the right
cartridge position.
4. Installation Checkout
Check the filter cartridge connections for leaks. Repair as needed.
Run water through the faucet for at least 5 minutes to remove
any air and carbon particles in the system.
Kohler Co.
Cartridges In Use
Hollow Fiber
Carbon Filter
Cartridge
Cartridge
(Green Label)
(Blue Label)
5
1367547-2-A