MAURER ZANTE Manual De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

B. Specifications
For outdoor use only
Uses butane, propane or LGP only
Burner pressure: 28/30/37/50 mbar
Max. wattage: 13,5 kW
Min. wattage: 5 kW
Consumption: 450 g/hr – 982 g/hr
Height: 2240 mm (88.2")
C. Countries of destination, pressure, and injector openings
Model
Countries of Destination
Category
Pressure (mbar)
Burner Injector
Nominal Heat Input
Tools needed:
Open end wrench 10 & 13 mm
Adjustable opening wrench (2) 20 cm (8") long
Slip joint pliers 23 cm (9") long
Philips screwdriver w/ medium blade
Spray bottle of soap solution for leakage test
Parts supplied:
Base
Tank housing
Post bracket
Assembly post
8 mm x 84.5 cm (L) galvanized steel pipe
Burner unit
Reflector 813 mm with 6 pcs washers Ø8 mm and 3 pcs M8 castle nuts
3 pcs 90 mm pins for reflector support
4 pcs bolts M6 x 10 mm for assembly post and burner
6 pcs bolts & nuts M6 x 30 mm for post and post brackets
3 pcs bolts M8 x 16 mm for post brackets and base
Mod. ZANTE (PH01-S)
AT, BE, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, LT, LU, LV,
MT, NL, NO, PL, PT, SE, SI, SK, TR
I3+
28-30/37
1.9 mm
13,5kW
ASSEMBLY PARTS
This appliance required regulator that is
defined under the GAS REQUIREMENTS, or
check with your gas supplier
I3 B/P
28-30
1.9 mm
WARNING
I3 B/P
30
1.9 mm
I3 B/P
50
1.7 mm