PROBLEM
Burner will not light
Burner flame goes off immediately
after ignition
Delayed ignition
Inadequate combustion on burner
Burner flame is low
Emitter glows uneven
Slight smoke and odor during initial
operation
Thick black smoke
Heater produces a whistling noise
when burner is lit.
Heater produces a clicking noise
just after burner is lit or turned off.
Gas odor even when control knob
is in OFF position
PROBLEMS CHECK LIST
PROBABLE CAUSE
Burner injector clogged.
Low gas supply pressure.
Low gas pressure
Main burner carry over ports
clogged.
Low gas supply pressure
Not enough air.
Supply hose is bent or twisted
Blockage in burner injector
Blockage in burner injector
Base is not on a level surface
Low gas pressure
Residue from manufacturing
processes.
Blockage in burner
Air passageways blocked.
Air in the gas line.
Metal expanding and
contracting, respectively.
Gas leaks.
Gas control defective.
SOLUTION
Clean burner injector.
Call your gas supplier.
Call your gas supplier.
Clean main burner ports.
Call your gas supplier.
Check air passageways and
burners for dirt and debris, and
clean with compressed air.
Straighten hose and perform
leak test on hose.
Clean or replace burner
injector.
Clean or replace burner
injector.
Place heater on a level surface.
Replace cylinder with a new
cylinder.
Will stop after approx. 30
minutes of operation.
Turn off the heater and let it
cool. Remove blockage and
clean burner inside and
outside.
Check minimum installation
clearances and air
passageways for debris.
Operate burner until the air is
completely purged.
This is common with heaters. If
noise is excessive, contact a
qualified person.
Locate and correct leaks
immediately.
Replace gas control.