Temporary muting the Alarm
In the event of a false alarm, e.g. caused by heavy smoke development during cooking or high dust levels, the
alarm tone can be muted for approx. 10 minutes. It is essential to ensure that the alarm was not triggered by a fire!
To mute the alarm temporarily, press the TEST button. Then open doors and windows to clean the air. If after 10
minutes the air still contains a high number of combustion particles, the alarm will sound again. The mute function
can be repeated as often as required by pressing the TEST button. This function cannot be activated if there is
excessive smoke. To deactivate the mute function, press the TEST button!
Recurrent self-test of the smoke alarm detector on its function:
The smoke alarm detector performs every 30-40 seconds a self-test. You can see this by a short blink of the LED.
Explanation of the LED modes :
LED flashes every 40 seconds:
LED flashes every second and alarm sounds:
LED flashes every 8 seconds:
LED flashes every 40 seconds and a short
alarm tone sounds:
Installation (Fig.8) :
1: Dowel
2. Mounting ring
3. Holes for screws for fixing
4: Screw
5: Retainer of the bayonet connection
Attention:
Before drilling the mounting holes, make sure that there are no gas, electricity or water pipes at the
drilling location that could be damaged by this!
Attention
: The device is only ready for operation if the case is properly attached to the mounting base. Otherwise
the battery is deactivated and the smoke alarm is not ready for use.
Since smoke rises to the top and spreads horizontally, install the smoke detector in the middle of the room if possible.
Observe a minimum distance of 0.5m from the side wall and 0.6m from the corner of the room, as well as a maximum
installation height of 6m (see Fig.6).
Remove the mounting plate located on the back of the housing by turning it counterclockwise.
Select an easily accessible installation location, as the smoke alarm detector must be checked weekly for
proper functioning!
Hold the mounting base to the position on the ceiling where you want to attach the unit. Then draw the holes
for the drill holes on the ceiling with a pencil.
Then drill two holes (Ø 6mm). Take the two plugs included in the delivery and insert them into the drilled
holes.
Screw the mounting base to the ceiling. The screws are included in the delivery.
Attach the housing to the mounting base by turning it clockwise until it clicks into place.
Dismantling lock: To prevent the smoke detector from being dismantled, for example by unauthorised
persons, we recommend the dismantling lock (see Fig.9).
The smoke alarm detector is working properly..
TEST button is pressed or the alarm has been triggered by
smoke.
The device is in the silent mode
Battery is low.
15