Adjust so that the gap between
the Flat Target solenoid
and the solenoid plunger
is approx. 0.5mm
Solenoid plunger
a
Solenoid spring
Flat target solenioid
b
Flange socket head
screws (M5x8)
Make sure that the main arm
comes in contact with the
rubber stopper D
Solenoid plunger
Main arm
Flat target (U)/(L) position
detector sensor
Flat target (U)/(L) solenoid
Rubber stopper D
Stopper D