Hydraulic connections
The heat pump should be connected to a filtration circuit after water pump and filtration system, using a filter to avoid
dirt or rubble in the machine.
If your installation is equipped with water treatment devices (chlorine, brome feeder, saltwater chlorine generator, others)
this machine must be installed before the water treatment devices, with a non-return check valve between the
machine and water treatment devices.
Inlet water tube must be connected to bottom connection labeled:
Outlet water tube must be connected to top connection labeled:
Water tubes must be fixed on the floor or the walls, so the heat pump will not support the weight of the water inside the
plumbing.
Electrical connections
Electric supply voltage and current values must correspond to the ones indicated on the heat pump.
Plug connector must be protected from weather and humidity with an appropriate device.
Example :
Only a certifyed electrician can confirm if your electrical installation is in conformity with local law in force.
Power supply must be equipped with grounding, circuit breaker and 30 mA differential protection.
The plug provided with the machine is equipped with an additional 10 mA differential security with manual reset button.
The heat pump must work in the same time as the water pump.