TECHNICAL SPECIFICATIONS
THERMAL CAPACITY
MODEL
in Kw
Min.
Max.
DRAGO P1
6
20
Standard natural gas nozzle bore
The pressure of the gas when the burner is lit must be 13
Standard LPG nozzle bore
The pressure of the gas when the burner is lit must be 30
GAS PRESSURE
in Kcal/h
in mbar
Min.
Max.
Min.
5.000
17.000
10
∅ ∅ ∅ ∅
2.25
∅ ∅ ∅ ∅
GAS VOLUME
in Nm3 /h
Max.
Min.
Max
30
0,60
3,50
4.00
GAS CONNECTION
WEIGHT
In inches
in Kg
1/2
4
20 mbar.
35 mbar.
29