tau K590M Guía Para La Instalación página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
6. STROKE SETTINGS PROCEDURE WITH OR WITHOUT SLOWDOWN (SETUP)
WARNING: The learning process has to be done even if ENCODER function is
disabled (DIP 11 OFF).
It is recommended to start the learning process already on the FCC closing limit switch.
Press the PROG key and keep it pressed until the DL1R and DL1V leds start flashing quickly. After re-
leasing it, the procedure carries out the following steps:
1_If the automation is already on the FCC limit switch, it goes directly to point 2.
Otherwise, if the automation is not on the FCC, it starts to look for the closing limit switch;
If the automation opens instead of closing, stop the learning process (by cutting the
photocells or opening the STOP contact), invert DIP 10 and continue the learning process
by pressing PROG briefly.
2_ The automation starts to measure the stroke from FCC to the opening limit switch FCA;
WARNING: - SETTING SLOWDOWN: (skip this procedure to disable slowdown) During
the opening cycle press PROG or close the OPEN/CLOSE contact at the desired position
where to start the slowdown.
3_ Once the opening is done, the automation starts to measure the stroke from the opening limit
switch FCA to the closing limit switch FCA;
SETTING SLOWDOWN: (skip this procedure to disable slowdown) During the opening cy-
cle press PROG or close the OPEN/CLOSE contact at the desired position where to start
the slowdown.
4_ The green led DL1V will flash every 4 sec. Learning process procedure is terminated.
WARNING: if during the learning process either the STOP, or PHOTOCELLS or SAFETY
EDGE contact will be opened the automation stops. By pressing PROG or closing the
OPEN/CLOSE contact the learning process starts again from pont nr. 1
7. 433.92 MHz BUILT-IN RADIO RECEIVER
The radio receiver can learn up to a maximum of 30 rolling codes (BUG2R, BUG4R, K-SLIM-RP, T-4RP)
which can be set on both the two channels as desired.
The first channel directly commands the control board for opening the automatic device; the second
channel commands a relay for a N.O. dry contact (terminals 12 and 13, max. 24 Vac, 1 A).
LEARNING PROCEDURE FOR TRANSMITTERS
CH1 = OPEN/CLOSE
1_ press button CH1 briefly to associate a transmitter with the OPEN/CLOSE function;
2_ LED (green) DL1V turns on to indicate that the code learning mode has been activated (if no code
is entered within 10 seconds, the board exits the transmitters learning mode);
3_ press the desired channel of the transmitter to be memorized;
4_ the LED (green) DL1V turns off to indicate saving is complete and then turn on immediately waiting
for another transmitter to be memorized (if this is not the case, try to re-transmit or wait 5 seconds
and restart from point 1);
5_ to memorise other transmitters, press the desired channel of the new transmitter within 5 sec
otherwise the learning procedure will be automatically closed and LED (green) DL1V turns off. To
repeat the procedure to learn new remote controls start again from point 1 (up to a maximum of
30 transmitters);
6_ to memorise codes on the 2nd channel, repeat the procedure from point 1 using button CH2 in-
stead of CH1; (in this case the red/ green leds DL1R and DL1V will light up);
7_ to program transmitters into the third channel, repeat procedure from point 1 using CH1 and CH2
buttons at the same time (DL8 will turn on red);
If the maximum number of radio controls is reached (30), the DL1V (green) led for CH1
and the DL1R (red) led for CH2 flash for about 3 seconds without however, carrying out
the memorization.
CH2 = 2nd channel
18
CH3 = 3rd channel (PEDESTRIAN)

Publicidad

Tabla de contenido
loading