Horizont Green Line Bio 10862 Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Table 12 (9V battery)
Remaining capacity
Flashing
green
light
Flashing
red/green
5-15
%
light
Flashing
red
5
%
light
Replace the battery at the latest when 95% discharged (only 5% charge capacity left).
The battery indicator (LED2) lights up:
Table 13 (12V rechargeable battery)
Remaining capacity
Flashing light
green
Flashing light
red/green
20-40%
Flashing light
red
0-20%
The rechargeable battery must be recharged at the latest when discharged down to 20% (only 80% charge capacity left) to
prevent a flat battery. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these figures to vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied - cover panel )
6. Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
● Switch off energizer
● Disconnect entire energy supply from the energizer.
● Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compati-
ble manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety &
environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
7. Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
12
Battery good
15-100%
Replace battery
Battery fully depleted
9V battery - immediately replace
Rechargeable battery good
40-100%
Charge the battery
Rechargeable battery absolute-
ly depleted
Table 14
Faults
Display
Battery under 15% capacity
LED1 flashes alternately red/green
Battery under 5% capacity
LED1 flashes red
Rechargeable battery under
LED2 flashes alternately red/green
40% capacity
Rechargeable battery under
LED2 flashes red
20% capacity
Corrective action
Change batteries
Change batteries
Charge the battery
Charge the battery
13