Descargar Imprimir esta página

Battery Replacement; Troubleshooting - TFA 60.1503 Instrucciones De Uso

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
TFA_No_60.1503_Anl_MULTI_12_20
30.11.2020
17:05 Uhr
Bedienungsanleitung
Operating Instructions
A
G
B
C D E
Seite 2
Radio-controlled alarm clock with double alarm bells
Thank you for choosing this instrument from TFA.
1. Before you use this product
• Please make sure you read the instruction manual carefully.
• Following and respecting the instructions in your manual will prevent damage to your
instrument and loss of your statutory rights arising from defects due to incorrect use.
• We shall not be liable for any damage occurring as a result of non-following of these
instructions.
• Please take particular note of the safety advice!
• Please keep this instruction manual safe for future reference.
2. Delivery contents
• Radio-controlled alarm clock
3. Field of operation and all the benefits of your new instrument at a glance
• Radio-controlled clock with highest precision
• Analogue display with fluorescent clock hands
• Double alarm bells made of metal
• Snooze function
• Backlight
4. For your safety
• This product is exclusively intended for the field of application described above. It should
only be used as described in your instruction manual.
• Unauthorised repairs, modifications or changes to the product are prohibited.
Caution!
Risk of injury:
• Keep this device and the battery out of reach of children.
• Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swal-
lowed, this can lead to serious internal burns and death within two hours. If you suspect a
battery could have been swallowed or otherwise caught in the body, seek medical help
immediately.
• Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of
explosion!
• Low batteries should be changed as soon as possible to prevent damage caused by leaking.
• Wear chemical-resistant protective gloves and safety glasses when handling leaking bat-
teries.
Cat.-No. 60.1503
Important information on product safety!
• Do not place your product near extreme temperatures, vibrations or shocks. Protect it
from moisture.
5. Elements
Buttons
A: ON/OFF switch
C: RESET button
E: SET button
Housing
G: Battery compartment
F
6. Getting started
• Open the battery compartment and insert one new battery 1,5 V C, ensure that the polari-
ty is correct.
• Your clock is ready for use.
• The clock's hands will move to 12 o'clock and the clock will try to receive the radio signal (3 -
12 minutes).
• When the time code is received, the radio-controlled time will be shown.
• Twelve times a day the clock will receive the radio signal.
• Manual initialization can be helpful. Press and hold REC button for 5 seconds. The clock's
hands will move to 12 o'clock and the clock will try to receive the radio signal (3 - 12 min-
utes) again.
• If the clock cannot detect the DCF-signal (for example due to disturbances, transmitting
distance, etc.), the time can be set manually. The clock will then work as a normal quartz
clock. (See: Manual setting of the clock).
Note for radio-controlled Time DCF
The time base for the radio-controlled time is a caesium atomic clock operated by the
Physikalisch Technische Bundesanstalt Braunschweig. It has a time deviation of less than one
second in one million years. The time is coded and transmitted from Mainflingen near Frank-
furt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approximately
1,500 km. Your radio-controlled clock receives this signal and converts it to show the precise
time. Changeover from summer time or winter time is automatic. The quality of the recep-
tion depends mainly on the geographic location. Normally there should be no reception
problems within a 1,500 km radius around Frankfurt.
Please take note of the following:
• The recommended distance to any interfering sources like computer monitors or TV sets is
at least 1.5 - 2 metres.
• Inside ferro-concrete rooms (basements, superstructures), the received signal is naturally
weakened. In extreme cases, please place the unit close to a window to improve the recep-
tion.
• During nighttime, the atmospheric interference is usually less severe and reception is pos-
sible in most cases. A single daily reception is adequate to keep the accuracy deviation
Cat.-No. 60.1503
under 1 second.
Radio-controlled alarm clock with double alarm bells
7. Operation
7.1 Manual setting of the clock
• Press and hold the SET button for five seconds.
• Now hold the button until the desired time is indicated.
• Press the button briefly and the clock's hand will move minute by minute.
• After the setting the clock's second hand will move forward again.
• The manually set time will be overwritten by the DCF time when the signal is received
7.2 Setting of the alarm clock
• Turn the alarm dial and set your respective alarm time (in direction of the arrow).
• To activate the alarm function, move the ON/OFF switch to ON.
• Instruction manual
• When the alarm time is reached, the alarm will ring.
• When the alarm rings, press SNOOZE/LIGHT button and the snooze function will be acti-
• Move the ON/OFF switch to OFF, the alarm function will be deactivated.
7.3 Backlight
• Press the SNOOZE/LIGHT button. The backlight will come on for 3 seconds.
8. Care and maintenance
• Clean your clock with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the battery if you do not use the product for a long period of time.
• Keep your clock in a dry place.

8.1 Battery replacement

• Replace the battery when the functions of the instrument become weak.
• Open the battery compartment and insert one new battery 1,5 V C. Make sure the polarity

9. Troubleshooting

Problems
No movement
of the clock's hands
No DCF reception
Incorrect indication
If your device fails to work despite these measures contact the supplier from whom you pur-
B: Dial for the alarm time
chased it.
D: REC button
F: SNOOZE/LIGHT button
10. Waste disposal
This product has been manufactured using high-grade materials and components which can
be recycled and reused.
11. Specifications
Power consumption:
Housing dimension:
Weight:
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are cor-
rect at the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply entering the
product number in the search box.
EU declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 60.1503 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following Internet address:
www.tfa-dostmann.de/service/downloads/ce
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany
successfully.
vated. The alarm will be interrupted for 5 minutes.
is correct. Close the battery compartment again.
Solutions
➜ Ensure that the battery polarity is correct
➜ Change the battery
➜ Hold REC button for 5 min. and start a new reception
➜ Choose another place for your clock
➜ Check if there is any source of interference
➜ Wait for attempted reception during the night
➜ Manual setting of clock
➜ Restart the device according to the manual or use a pin to press
the RESET button
➜ Change the battery
Never dispose of empty batteries and rechargeable batteries in household waste.
As a consumer, you are legally required to take them to your retail store or to
appropriate collection sites depending on national or local regulations in order
to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste Electrical and Elec-
tronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is obligat-
ed to take end-of-life devices to a designated collection point for the disposal of
electrical and electronic equipment, in order to ensure environmentally-compati-
ble disposal.
Battery 1 x 1.5 V C (not included)
Use alkaline batteries
130 x 70 x 180 mm
367 g (instrument only)
12/20