MACHINE COMPONENTS

Operator Control Column
The operator control column is located at the rear of
the machine. This column has components that
control various machine functions.
Drive System Control
 At the top on both sides of the control column are
two (2) rubber twist grips. These grips rotate
forward and backward to control the direction and
speed of the machine.
 They also activate the Brush Motor so it is only on
when the machine is moving. The farther the grips
are rotated, the faster the machine will move.
 These twist grips have a safety feature that returns
the machine to the neutral position when the
handles are released.
Battery Meter
The battery meter is located in the back of the control
column cover and has two uses. It shows the state of
charge of batteries during operation and flashes fault
codes when there is a problem with the machine.
 The rate of charge is indicated by numbers. The
higher the number the greater the charge in the
battery pack.
 When there is a fault with the machine, the Battery
Meter will flash an "F" followed by a number.
 See Trouble Shooting Chart for more
information.
Battery Charger
The battery charger is located on top of the battery
box cover.
 This high efficiency battery charger is designed for
onboard operation.
Master Switch
 The master switch is located on the top right side
of the control column and it turns the machine on
and off.
 If the brush switch is on and the brush head is
down or the twist grips are not in the neutral
position the machine will not turn on. A flashing
fault code will appear on the battery meter. See the
bottom of the decal on control column cover and
correct the problem.
 The control system will automatically turn the
machine off if it sets idle for 10 minutes. Turned off
the master and brush switch and then turn the
master switch back on to restart.
Hour Meter
 The hour meter is located under the Master Switch
and counts the hours the brush motor is on. The
hour meter is used for indicating maintenance
intervals. The hour meter cannot be reset.
 See maintenance section for maintenance
intervals.
Fuse Holder
 The fuse holder is located under the Hour Meter. It
houses a 2 AMP fuse.
Key Switch
 A Key Switch is Optional and will be located above
the hour meter when installed. The key switch and
master switch will both need to be used to turn the
machine on and off.

Publicidad

Tabla de contenido
loading

Productos relacionados para NSS Enterprises CHARGER 2717 DB

Este manual también es adecuado para:

Charger 2022 db

Tabla de contenido