Daily Maintenance (continued)
Empty the filter bag daily or when it is
approximately one-half (1/2) full.
Charging Batteries
Recharge the batteries when indicated by the
Battery Meter.
Never let the batteries sit overnight after the
machine has been run for 1hr or more since last
recharge.
NEVER let the electrolyte level fall below the tops
of the plates. This will damage the batteries
immediately, and void the warranty.
Check charger cord for exposed wires and
damaged plugs before using.
To recharge the batteries plug the charger cord into
the charger located on top of the machine and then
into an electrical outlet.
When the cord is plugged into an outlet the
machine will automatically become disabled.
Charge the batteries with the cover open when
possible to reduce heat build up in the batteries.
See charging instructions for more details.
ALWAYS wear eye protection, rubber gloves and
protective clothing to avoid contact with battery
acid when working around batteries.
After charging batteries check the water level of
each battery cell and add distilled water as
required to level specified by battery manufacturer.
Check and verify that all battery connections are
clean and tight.
Wipe machine down with a damp cloth.
NEVER spray this machine with water or any
liquids.
ALWAYS Check the tilt switch for proper
operation. With the master switch turned off, put
the brush head into the pad change position. Turn
the brush switch on then the master switch on, the
machine should turn on.
If the machine does not turn on and the battery
meter is flashing a one, the tilt switch has failed.
DO NOT use the machine until the tilt switch has
been replaced.
Opportunity Charging
Opportunity charging is charging the batteries when
an opportunity presents itself, such as during breaks,
and is done in addition to a full charge cycle.
Opportunity charging is recommended, as this extra
charging time will help raise the operating voltage of
the batteries, and will help ensure maximum runtime
and cycle life.
See Monthly Maintenance and Operating Battery
Charger Instructions for equalizing your batteries
especially if you have been opportunity charging
your machine.
Weekly Maintenance (Every 25 Hrs)
Verify all daily maintenance has been performed.
Inspect the Flexiwall Shield for dents around the
outside edge and cracks in the plastic.
Check that the Brush and Retaining Band are
properly installed.
Remove dirt build up on the brush along the
bottom of the Flexiwall Shield.
A damaged Flexiwall Shield Assembly will greatly
reduce dust control capabilities of the machine.