Prepare Cutout Opening - Furrion FWH09A Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Prepare Cutout Opening

1. Choose a location to place the appliance, based on the
following criteria:
− DO NOT install on the rear or front of the RV to
minimize contamination from road grim, debris and wet
roads when traveling.
− Do not install the appliance in an outdoor enclosed
area.
− DO NOT install the appliance in any location where the
exhaust vent may be covered or obstructed when a
swing door, bag door, slide out, pop up, etc. is partially
or fully extended.
− DO NOT install this appliance on any door or slide out
area.
− Do not install the appliance where the access door is
less than
- 9" (229mm) from any opening into the vehicle
- 36" (914) from any motor driven air intake
- 36" (914mm) from the any gas tank connection or
ventilation.
NOTE: These are guidelines, refer to NFP1192, Z240
RV edition for specific requirements.
− Choose a convenient location where supply water, LP
gas, and 12V DC is accessible to the back side of the
appliance for installation and servicing.
− The water heater is designed to be installed on a flat
floor (made of Wood or Linoleum) or a fixed platform.
− It is recommended that the appliance be located in a
central location to the hot water loads.
− Choose a location where clearances to combustible
surfaces and the appliance are:
- 1" to top surface.
- 0" to all other surfaces.
NOTE: To install on a carpeted area, a metal or wood panel that
extends at least 3 inches beyond the width and depth of the water
heater is required to install under the unit.
2. Create a cutout with the following dimensions A and B of
Fig. 2.
NOTE: The opening for the water heater should be right
angle corners.
Fig. 2
A
12 5/8"~ 12 3/4"
12 3/4"~ 12 13/16"
(321~325mm)
(324~326mm)
3. Make sure that the front edge of the opening is
surrounded by a solid frame to firmly anchor the water
heater. If needed, construct the opening by using
1.5" x 1.5" min. wood or aluminum framing.
5
A
Dimension
B
C
Min. 23 1/2"
(Min. 597mm)
NOTE:
− Fiberglass, filon, and corrugated aluminum (Mesa 1")
are all acceptable exterior wall siding solutions.
− The exterior wall opening must be the same dimensions
with no radius corners.
4. Refer to depth "C" for minimum rear clearances, for such
items as cabinets, appliances and utility entry locations.
5. Refer to Fig. 3 for adequate spacing from other items on
the RV wall to the door assembly.
Fig. 3
Door Assembly
FWH09EA-PS
FWH41EA-PS
FWH46EA-PS
6. Make sure the appliance is supported by a solid floor or
platform with adequate weight-bearing capacity. (Fig. 4)
Fig. 4
7. If necessary, create a platform to support the water heater.
Fig. 5 and Fig. 6 are some common solutions. Ensure
the platform is level front to back, and side to side after
securing to the RV.
A
Fig. 5
Fig. 6
A
Cutout
Spacing
B
A
Min. 1 3/4" (45mm)
Min. 2 3/4" (70mm)
Min. 2 3/4" (70mm)
Flush Platform
Wooden Mat
Flush Platform
Wooden Mat
B
Min. 1 7/8" (47mm)
Min. 1 7/8" (47mm)
Min. 2 13/16" (72mm)
A

Publicidad

Tabla de contenido
loading

Tabla de contenido