3.2.6 Settings Alarm
With this sub-menu it is possible to set some protections for your Pool such as:
Stabilization time (1sec – 60 min): when the system is switched on, it waits
♦
Stabilization time before starting to dose (the probe readings need few minutes to
be stabilized)
pH dosing alarm (5min – 60 min / OFF) if the pH pump doses its product and there
♦
is no variation of pH (0.05 pH) during the set time, the system gives alarm and stop
to dose. The alarm is automatically disables near the set point (when the difference
between the measurement of pH and the set - point is less than 0.2 pH but only if
the pump is not dosing at maximum flow rate)
Rx dosing alarm (5min – 60 min / OFF) if the Rx pump doses its product and there
♦
is no variation of Rx (5 mV) during the set time, the system gives alarm and stop to
dose. The alarm is automatically disables near the set point (when the difference
between the measurement of Rx and the set - point is less than 20 mV but only if
the pump is not dosing at maximum speed)
Pumps ON Alarm (5min – 60 min / OFF): if both the pumps doses for a period
♦
longer than the set time the system gives alarm and stop to dose
Flow Control: the panel can be equipped with a flow-sensor, that detect the flow
♦
inside the probe holder, if the flow is over the system gives alarm and stop to dose.
A-TECHNOPOOL PH-RX
28/06/2010
9/64