Kronus 2
Temperature, Humidity and CO² Controller
Easy Guide
VANCOUVER, W ASHINGTON U.S.A.
Instructions for Use
1. Mount Kronus 2 in a secure area, but away
from moisture, sprays, pesticides, etc.
2. Plug CO² Controller (Atlas 1) or CO² Timer (Apollo 1)
into the "CO² Output" outlet.
3. Turn the CO² Controller or CO² Timer "ON".
4. Plug fan into the "Exhaust Fan Output" outlet.
5. Turn exhaust fan 'ON' to the highest setting.
6. Place remote sensor in grow area at
TM
plant canopy height.
7. Set the 'Temperature' and 'Humidity' control
dials at the preferred temperature and humidity
levels for your garden.
8. Plug the Kronus 2 into a 120 Volt/15 Amp outlet.
Note: A surge protection device is recommended.
9. Turn Kronus 2 to the "ON" position.
10. The Kronus 2 will now activate and deactivate the
equipment based on your preferred settings
Controller Specifi cations
Size: 9.5" H x 8.5" W x 2.5" D
Weight: 3 lbs.
Voltage Input: 120 Volts
Voltage Output: 120 Volts
Maximum Amperage: 15 Amps
Hertz: 60 Hz
Min/Max Humidity Control Level:
40% RH to 90% RH
(non-condensing)
Humidity Accuracy: +/- 5%
Min/Max Temperature Control
Level: 45° to 95°F (7° - 35°C)
Temperature Accuracy: +/- 2°
Cord set: 6 foot/14 AWG
Storage Temperature: 32° to
120°F (0° - 49°C)
Operating Temperature: 45° to
95°F (7° – 35° C)
www.titancontrols.net
For technical assistance call us at
1-888-80-Titan or 1-888-808-4826.
Controlling a CO² Tank or
CO² Generator & Exhaust Fan
2
CO
Generator
Atlas 1
CO² Monitor
and Controller
OR
2
CO
Tank
Remote
120 Volt
Power in
®
Kronus 2
Exhaust Fan
Kronus
Sensor