EAS ELECTRIC NT-03A Manual De Instrucciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

(6) Left and right swinging (Internal pendulum wind)
① Pressing this key in the dehumidification mode, the internal pendulum wind stays unchanged
according to the state before switching.
② Pressing this key in the other modes, the internal pendulum switches by "swing, stop, swing"
circularly.
① When the first power on, the remote controller is set to the automatic wind speed by default. In
(7) "FAN -"
dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing
② Pressing this key in the other modes, the wind speed switches by "automatic wind speed, high
the wind speed key, there is no response to the remote controller.
speed, middle speed, low speed, automatic wind speed " circularly.
① When the first power on, the remote controller is set to the automatic wind speed by default. In
(8) "FAN +"
dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing
② Pressing this key in the other modes, the wind speed switches by "automatic wind speed, low
the wind speed key, there is no response to the remote controller.
speed, middle speed, high speed, automatic wind speed " circularly.
① Under the shutdown state, press this key to set the opening time, range from 1 hour to 24
(9) Timer
② Under the boot state, press this key to set the shutdown time, range from 1 hour to 24 hour.
hour.
③ The timing time is according to the cycle of "1h, 2h, ......, 23h, 24h, cancel, 1h".
④ Exit timing adjustment after 3 seconds without key pressing.
① Extension code remote controller has the effect. The remote controller is no TURBO by
(10) TURBO
default, and the TURBO key will not work in automatic mode, dehumidification mode and fan
② Pressing this key in the cooling or heating mode, the TURBO mode switches between
mode.
opening and closing. When in the TURBO mode, it does not display the wind speed.
③ If the air conditioner has four gear wind speeds, the TURBO icon will light up and the fan will
Switching mode or entering sleep function will close TURBO mode.
run in the fourth gear wind speed by pressing this key.
(11) ECON
① The remote controller is no ECON by default, and the ECON key will not work in automatic
mode, dehumidification mode and fan mode.
② Pressing this key in the cooling or heating mode, the ECON mode switches between opening
and closing. When in the ECON mode, the setting temperature is set to 26℃ (77℉) and other
settings are unchanged. If closing ECON mode, the remote controller will recover to the
10
V.1

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido