Operating Instructions • Warning Information • Parts Breakdown
Adjustable Pressure Range . . . . . . . .5-120 PSIG ( .3-8 bar)
Maximum Service Pressure . . . . . . . . . . 140 PSIG (9 .7 bar)
Maximum Air Flow . . . . . . . . . . . . . . . . . . . . . . 575 SCFM
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 .4 fl . oz .
AlwAys reAd
instructions
before using
power tools
AlwAys weAr
sAfety goggles
weAr heAring
protection
Avoid
prolonged
exposure to
vibrAtion
AL24
FILTER, LUBRICATOR
S P E C I F I C A T I O N S
some dust created by power sanding, sawing, grinding, drilling, and other construction
activities contains chemicals known to cause cancer, birth defects or other reproductive
harm. some examples of these chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement and other masonry products, and
• arsenic and chromium from chemically-treated lumber.
your risk from these exposures varies, depending on how often you do this type of
work. to reduce your exposure to these chemicals: work in a well ventilated area, and
work with approved safety equipment, such as those dust masks that are specially
designed to filter out microscopic particles.
Operating Temperature Range . . . . . . . 41 - 140ºF (5-60ºC)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 .7 lbs .
Dimensions . . . . . . . . . . . . . . . . . W 6 .3" x H 9 .0" x D 4 .0"
Copyright © Professional Tool Products, 2012
1
AL24
AL24
All rights reserved.
05/15/12

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Matco Tools AL24

  • Página 1 AL24 FILTER, LUBRICATOR AND REGULATOR UNIT Operating Instructions • Warning Information • Parts Breakdown S P E C I F I C A T I O N S AL24 Adjustable Pressure Range . . . . . . . .5-120 PSIG ( .3-8 bar) Operating Temperature Range .
  • Página 2 AL24 FILTER, LUBRICATOR AND REGULATOR UNIT WARNING fAiLure To oBserVe These WArnings couLd resuLT in inJury • Keep body working stance balanced and firm. Do This insTrucTion MAnuAL conTAins not overreach when operating the tool. iMporTAnT sAfeTy inforMATion. • Anticipate and be alert for sudden changes in motion reAd This insTrucTion MAnuAL cArefuLLy during start up and operation of any power tool.
  • Página 3 AL24 FILTER, LUBRICATOR AND REGULATOR UNIT reassembly, be sure bowl baffle (#6) and shatterguard (#3) are insTALLATion of fiLTer/reguLATor securely tightened. 1. Maximum air pressure to unit is 140 PSIG (9.7 BAR). 2. Mount the unit as close to the item to be protected as possible. 3. Direction of air flow is designated by an " " and " " on the WARNING! primary unit. Pressure systems can leak causing flying particles. 4. Position the water discharge valve (#12) with the " " pointing Wear safety goggles. (User and bystanders). upward. Read and follow instructions. 5. Proper water drainage should be allowed beneath the water Flying particles can cause injury. discharge valve (#12). Provide a container to catch the water...
  • Página 4 AL24 FILTER, LUBRICATOR AND REGULATOR UNIT 4. Be advised that the plastic parts could show signs of premature aging and discoloration if exposed to paints, inferior grade lubricants, detergents or other chemicals. WARNING: THIS UNIT IS NOT TO BE USED WITH ANY OTHER FLUIDS, ESPECIALLY FLAMMABLE LIQUIDS SUCH AS GASOLINE OR ALCOHOL. SERIOUS DAMAGE OR INJURY TO THE USER COULD RESULT. WArrAnTy Matco® air tool accessories are warranted against defects in materials or workmanship for a period of 1 year from original purchase. We will repair or replace at our option any defective part...
  • Página 5 AL24 FILTER, LUBRICATOR AND REGULATOR UNIT ITEM PART NO. DESCRIPTION QTY. Body RSAL2002 Bowl RSAL2003 Shatterguard RSAL2004 Fixed Ring RSAL2005 O-Ring Bowl Baffle RSAL2007 Filter Element Interceptor O-Ring 10 RSAL2010 O-Ring 11 RSAL2011 O-Ring 12 RSAL2012 Nut 13 RSAL2013 Piston...
  • Página 6: Unidad De Filtro, Lubricador Y Regulador

    AL24 UNIDAD DE FILTRO, LUBRICADOR Y REGULADOR instrucciones de operación • Inforación de Advertencia • Revisión de Refacciones E S P E C I F I C A C I O N E S AL24 Rango de presión ajustable . . . . . . . .5-120 PSIG ( .3-8 bar) Rango de temperatura de operación .
  • Página 7: Descripción

    AL24 UNIDAD DE FILTRO, LUBRICADOR Y REGULADOR ADVERTENCIA EL INCUMPLIMIENTO DE OBSERVAR ESTAS ADVERTENCIAS PUEDEN RESULTAR EN ALGUNA LESIÓN • Mantenga balanceada y firme la postura corporal de esTe MAnuAL insTrucciones trabajo. No se extra limite al operar esta herramienta. conTiene inforMAciÓn iMporTAnTe de seguridAd. LeA cuidAdosAMenTe esTe • Anticipe y sea alerto por cambios repentinos de...
  • Página 8: Regulación De La Presión De Aire

    AL24 UNIDAD DE FILTRO, LUBRICADOR Y REGULADOR deflector del plato (#6) en el contrasentido de las agujas del reloj insTALAciÓn deL fiLTro/reguLAdor 1. La máxima presión de aire a la unidad es de 140 PSIG (9.7 y extráigalo, siendo cuidadoso de no perder el interceptor (#8). El filtro (#7) ahora puede ser extraído y enjuagado de cualquier BARRAS). escombro. El filtro puede reinstalarse para uso repetido. 2. Monte la unidad lo más cercano posible al artículo a protegerse.
  • Página 9: Garantía

    AL24 UNIDAD DE FILTRO, LUBRICADOR Y REGULADOR ADVERTENCIA: ¡UN CORRIENTE DE AIRE PRESUIRZADO PUEDE OCASIONAR LESIONES SERIAS! 2. Desatornille el protector contra añicos en el sentido de las agujas del reloj y quítelos, siendo cuidadoso de no perder en anillo en O (#5). 3. Limpie el plato hondo transparente (#34) con un trapo limpio y seco. No use ningún químico el cual podría dañar el material del plato hondo. Al momento de ensamblarlo de nuevo, asegúrese que el anillo en O esté en la posición adecuada y que el protector...

Tabla de contenido