Operation:
Before operating, please ensure the installation and wire connection.
1. Operating by Remote control
Within 6M (60°C), direct the Remote Controller to the Receiver. Press "ON
/ OFF" to start normal air and then press "Warm" to start warm air.
When in normal air, press "ON/OFF" to shutdown the operation. If in warm
air, press "ON/OFF", the air curtain will be in delay condition for 3 minutes
(Red indicated lamp glimmering) and then shut down.
2. Operating by Receiver directly
Push "Warm/Normal/Off" button to choose what your desired. When push
"Off", the air curtain will be in delay condition for 3 minutes and then auto-
matic shut down.

Maintenance and repair:

1. Unplug the unit from any power source prior checking or maintenance.
2. Keep electric motor or other parts away from moisture to avoid short cir -
cuit.
3. Regular checking and maintenance is recommended, clean all the dust
off. Simply damp with mild detergent by a cloth for cleaning.
4. Detach the unit only by professionals.
Specifications:
Model
Part Num.
MU-ECO
09/6R
EC 06 414
09/6R3 ph
EC 06 417
12/8R
EC 06 415
12/8R3 ph
EC 06 418
15/8R
EC 06 416
15/8R3 ph
EC 06 419
NOTE: Rated voltage and frequency are stated as per rating label.
Power
(W)
Length
Normal
900 mm
160
1200
230
mm
1500
300
mm
7
Air
Noise level
speed
(m / s)
Warm
6160
7430
7
9300
Weight
(dB)
(kg)
55
20.2
57
23.2
59
29.0

Publicidad

Tabla de contenido
loading