Technical Data

Dimensions L x W x H
Weight
Mains supply voltage
Power consumption
Safety class
Fuse
Temperature range
Temperature accuracy
Temperature stability
Equipotential bonding
Display
Interface
Compressed air
Air consumption
Compressed air connection
Air flow rate
38
soldering
soldering
station
station
WX 1
WX 2
170 x 151 x 130 mm
6,69 x 5,94 x 5,12 inch
ca. 3,2 kg
ca. 3,2 kg
230 V, 50 Hz / 120 V, 60 Hz / 100 V 50/60 Hz
200 W
200 W (255 W)
I, antistatic housing
III, Soldering tool
T2 A (230 V)
T4 A (120 V)
Celsius:
100 - 450°C
Fahrenheit:
200 - 850°F
Controllable temperature range is tool-dependent
± 9 °C
± 17 °F
± 2 °C
± 4 °F
Via 3.5 mm pawl socket on back of unit
255 x 128 dots / Backlighting
The control unit has a front-side USB port which you can use for instal-
ling firmware updates, configuring, monitoring and data logging (using
WX Monitor Software).
-
-
-
-
desoldering
Hot air station
station
WXD 2
WXA 2
ca. 3,8 kg
ca. 3,8 kg
200 W (255 W)
200 W (255 W)
(550°C)
(999°F)
Inlet pressure
Inlet pressure
400 - 600 kPA
400 - 600 kPA
(58-87 psi);
(58-87 psi) oil
oil-free, dry
free, dry com-
compressed air
pressed air or
nitrogen (N2)
35 l / min
-
max vacuum 75
kPA (10,9 psi)
Compressed air
Compressed air
hose
hose
outer diameter
outer diameter
6 mm (0,24")
6 mm (0,24")
approx. 0-18 l/
min at 6 bar

Publicidad