EMERGENCY OPENING WITH KEY
1) Use the emergency key to open the Safe, keep the Safe door open and adjust the locking pins to their
unlocked position. It will not be possible to remove the key;
2) Enter the code "1234" and press "ENTER" on the Safe; "CLOSE" will be displayed; however, the locking pins
cannot be closed; at the same time, firmly turn the key until you hear the motor start. The Safe display will
read "b-loc" and the locking pins will close.
The emergency key can now be removed.
3) Key in "1234" to open the locking pins and keep the safe open for the next guest.
"HIDDEN CODE" FUNCTION
Press u to activate the Safe, then press the button t twice and u once, the device will beep twice. Access
is obtained to the hidden code function. Repeat the procedure to reset the code.
EMERGENCY
KEY

KEYPAD LOCK

If an incorrect code is entered 3 times, the keypad will lock for 15 min. The safe will display "HOLD **", "**"
indicates the time delay after which the keypad will be unlocked.
LIGHTING ACTIVATION AND DEACTIVATION
Activation: on opening the door, press the "RESET" key for 2 seconds to activate lighting. If the door is
not closed, lighting will deactivate itself after 15 seconds. If the door is closed, lighting will deactivate itself
automatically.