− Vigorously turn the pump housing counter-clockwise (bayonet lock) and remove together with O ring.
− Remove the screws, intermediate housing, O ring and impeller unit.
− Clean all parts in clear water with a brush.
− Check parts for damage and replace if necessary.
− Reassemble in the reverse order.
AquaMax Eco Premium 12000/16000:
− Remove the screws and pump housing.
− Pull off the impeller unit and flat seal.
Note: When pulling out the impeller unit, the journal bearing may come loose in the motor housing.
− Clean all parts in clear water with a brush.
− Check parts for damage and replace if necessary.
− Reassemble in the reverse order.
Note: Check that the journal bearing in the motor housing is correctly seated. If necessary, press the journal bearing
with the wide grooves at the front into the seat in the motor housing.
AquaMax Eco Premium 20000:
− Take out the screws and remove the two adapter plates, the pump housing with O ring and the intermediate hous-
ing.
− Pull off the impeller unit and flat seal.
Note: When pulling out the impeller unit, the journal bearing may come loose in the motor housing.
− Clean all parts in clear water with a brush.
− Check parts for damage and replace if necessary.
− Reassemble in the reverse order.
Note: Check that the journal bearing in the motor housing is correctly seated. If necessary, press the journal bearing
with the wide grooves at the front into the seat in the motor housing.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Storage/Over-wintering
The unit is frost resistant to minus 20 °C. Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug
in water!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Wear parts
The impeller unit is a wearing part and does not fall under the warranty.