Oase LunAqua 10 Halogen Instrucciones De Uso página 10

Ocultar thumbs Ver también para LunAqua 10 Halogen:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
- EN -
Set-up and start-up
The unit comes without bulbs and transformer. Please refer to „Bulb replacement" when fitting the bulb. When set up
above the water level, maintain a safety distance of at least 50 cm from combustible material. Ensure a safe seating.
Do not cover the unit. Danger of fire! A swivel bracket (4) can be fitted to the spotlight by means of a screw connection.
Position the unit such that it does not present a hazard for anybody. When fitting in the pond, fasten the unit on a suita-
ble base by means of the swivel bracket. The ground stake (5+6) can be used when installing the unit out of the water.
Connect the power plug of the spotlight to the socket of the transformer bush (2+3). Connect the transformer to the
power supply. Check the spotlight function.
Replacing the bulb (1)
Suitable bulb: max. 75 W Halogen GY6.35 (44 x 12 mm).
Adhere to the safety instructions! Disconnect the power! Undo the screw connection of the top section. Ensure that no
moisture can enter the unit. Remove and, if necessary, clean the top section and glass disk. Remove the bulb from the
housing. Insert a new bulb (do not touch with your hands, use a cloth or similar). Check the O-ring and replace, if dam-
aged. Reassemble the unit in the reverse order, connect to the power supply and perform a function check.
S
Malfunctions
Malfunction
Lamp does not light up
Light intensity decreases
Water in the spotlight housing
Light flickers
Cleaning
Adhere to the safety instructions! Carry out the work steps as specified under 'Replacing the bulbs'. Only use water
and a soft brush. Ensure that no moisture can enter the unit.
Wear parts
• Bulb
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
10
Cause
Power supply interrupted
Bulb defective
Bulb contacts corroded
Lamp glass soiled
Seal defective
Contacts corroded
www.oase-livingwater.com/spareparts
Remedy
Check power supply
Replace bulb
Clean contacts
Clean
Check sealing rings and replace, if necessary
Clean lamp pins

Publicidad

Tabla de contenido
loading

Tabla de contenido