Apply hydraulic fluid or O-ring lubricant to all O-rings and their mating surfaces to facilitate
installation. When installing an O-ring over a sharp edge, use a rolling action to avoid damage
to the O-ring.
Wherever assembled parts cause metal-to-metal contact, coat the surface with hydraulic fluid or
O-ring lubricant.

7. TECHNICAL FEATURES

Terminals / splices
Terminals and tubular splices
YAV – YSV – YSM – YCA - YCS
"C" type tap off connectors of Cu
"C" type tap off connectors of Al

8. ACCESSORIES

9. TROUBLESHOOTING GUIDE

Symptom/Problem
Dies difficult to install and
remove.
Loss of all resistance in pump
handles prior to completion of
crimp (blow-off).
Persistent problem with air
(even after bleeding).
External leakage of hydraulic
fluid.
Tool does not reach full
pressure (blow-off).
Ram does not fully retract.

10. GUARANTEE

The Y35 and Y35BH tool are guaranteed free of defects in material and workmanship for a period of
one year from the date of purchase. Any defect that show up within one year will be repaired or
replaced free of charge. As long as the tool was correctly used following the SBI's instructions.
After one year the units will be repaired in the factory and billed to the customer. The Y35/Y35BH tool
which has to be repaired (re-constructed in the factory, equipped with new spare parts, adjusted and
completely re-conditioned has to be sent (WITHOUT DIES) to SBI.
Together with the unit for repair, a repair order and a short description of the failure is required. AII
Y35/Y35BH toots re-constructed in the factory carry a new guarantee of six (6) months as from the
date of leaving the factory
All manuals and user guides at all-guides.com
Crimp
Accessories supplied
Box
Possible cause
Damaged die retaining housing on head
and/or ram.
Air in system.
Hydraulic fluid level low.
Excessive pump handle travel.
To determine this, fully open pump
handles. Measure the center-to-center
distance of the handle ends. This distance
should not exceed 432 mm.
Damaged seal or gasket.
Internal hydraulic leak.
Over-filled hydraulic fluid reservoir.
Damaged ram return spring.
Ram wiper ring/piston contaminated.
14
Section
2
(mm
)
Force developed
10 - 300
Length Y35
Length Y35BH
10 - 300
Weight Y35
10 - 300
Weight Y35BH
Rotatory head
10 - 150
Jaw opening
10 - 150
Head width
Accessories not supplied
Dies (according application)
Oil (ALFLUID, HYFLUID)
Test gauge kit (PT29279-2)
File down raised/deformed section.
Bleed hydraulic system.
Fill hydraulic fluid reservoir.
Contact with SBI
Contact with SBI.
Contact with SBI.
Consult Maintenance chapter
"Replacing hydraulic fluid"
Y35 Technical features
120 kN
575 mm
234 mm
6 kg
3.6 kg
180 º
24 mm
70 mm
Remedy