3E4723 Gallagher MBS100 MBS200 MBS400 MBS800 Mul -Power User Manual
TIPS & TROUBLESHOOTING
Turn off energizer before handling fence or ba ery connec ons.
Symptom
Problem
Energizer has
The internal
started to
temperature of the
run slowly
energizer is too high
Low ba ery capacity
Energizer
Ba ery has less
does not
than 10% capacity
operate
remaining
Energizer is Off
Faulty energizer
Electric fence
Faulty energizer
voltage is
below 3000V
or your stock
are escaping
Inadequate earthing
Loose connec ons
Solu on
Mount the energizer in a cool area, out of
direct sunlight and with adequate ven la on.
Check ba ery voltage using the ba ery check
mode. Replace with fully charged ba ery or
ensure solar panel is ge ng enough sun to
allow ba eries to charge.
Replace with fully charged ba ery or ensure
solar panel is ge ng enough sun to allow
ba eries to charge.
Check power source is connected. Ensure
mode selector switch is ON.
Have energizer repaired.
Disconnect energizer from fence and earth.
Measure across the fence and earth terminals
using a Gallagher fence volt meter. If the
voltage is less than 5000v, have energizer
repaired.
Improve the earth system by adding more
galvanised earth stakes to the earth system
un l the earth voltage is 200V or below.
Check the electrical connec ons are secure e.g.
from the fence to the red terminal, from the
earth system to the green terminal, at gates
etc.
17