Operation
Tap Button
Dimming
Rocker
• Tap once when unit is off -
Lights brighten smoothly to
Press to brighten
preset intensity.
Press to dim
• Tap once when unit is on -
Lights dim smoothly to off.
LEDs
• Tap twice quickly - Lights
Light level
brighten rapidly to full
indicators
intensity.
• Press and hold when unit
OFF
ON
is on - Activates delayed
fade-to-off. As the tap button
is held, the LEDs will begin
IMPORTANT NOTICE:
to flash. The first flashing
LED represents a 10 second
FASS - Front Accessible Service Switch - to replace bulb,
power may be conveniently removed by sliding FASS
fade to OFF. Each additional
switch to the left. For any procedure other than routine
flashing LED represents an
lamp replacement, power must be disconnected at
additional 10 seconds of
the main electrical panel.
delay before lights fade to
OFF (up to 60 seconds of
Power Failure Memory - Light(s) return to level prior to
power failure.
delay).
Infrared Wireless
Transmitter Operation
Point the transmitter at the Maestro IR Dimmer(s), then use the
buttons as outlined below.
BRIGHTEN:
ON FULL:
Tap once - lights brighten
Press to brighten lights
smoothly to full intensity.
DIM:
Press to dim lights.
OFF:
Tap once: Fade to off
ONE-TOUCH BUTTON:
Press and hold: 10–60 second
Tap once to recall your favorite
delayed fade to off.
light level.
To store your favorite level, set
This transmitter is compatible
dimmer to desired level, then
with most learning remote
press and hold for about 3
controls. Please see the
seconds until the dimmer LED
learning remote control
begins to flash. ("Off" is a valid
manufacturer's instructions for
preset level.)
programming information.
Note: If multiple Maestro IR Dimmers are installed in the same location they will
operate simultaneously.
Technical Assistance
If you have questions concerning the installation or operation of this product, call
the Lutron Technical Support Center. Please provide exact model number
when calling.
+1-800-523-9466 (U.S.A., Canada, and the Caribbean)
Other countries call +1-610-282-3800
Fax +1-610-282-3090
Internet: www.lutron.com
Troubleshooting
Symptom
Possible Cause
Light does not turn on or no
• Front Accessible Service Switch (FASS) on
LEDs turn on.
the Dimmer is switched to the left (see
Step 5).
• Light bulb(s) burned out.
• Breaker is off or tripped.
• Dimmer not wired correctly. (Ex: Neutral
not wired to Dimmer.)
Lamps flicker with low-voltage
• Wrong load type used. Verify that load is
loads.
electronic low-voltage.
LEDs do not turn OFF when
• The yellow and black wires are reversed.
FASS switch on the dimmer is
See wiring diagram in Step 4 for correct
in the OFF position (to the left).
wiring.
Lights cycle OFF and ON.
• Overload protection circuit active –
remove excess load to correct.
Dimmer does not respond to
• Transmitter batteries are installed
infrared wireless transmitter.
incorrectly.
• Transmitter batteries are dead or low.
• Transmitter is not aimed at the Dimmer.
• Transmitter is outside operating range.
• Dimmer has already received and
responded to command.
Dimmer does not respond to a
• Transmitter is not a programmable type
non-Lutron infrared wireless
transmitter (i.e. learnable or stored code).
transmitter.
• Transmitter was not set up properly.
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or
manufacture within one year after purchase. For warranty service, return unit to place of
purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-
paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED
WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS
WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR
REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM
IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL
OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES
ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,
DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE
UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from
state to state. Some states do not allow the exclusion or limitation of incidental or
consequential damages, or limitation on how long an implied warranty may last, so the above
limitations may not apply to you.
This product is covered under one or more of the following U.S. patents: 4,835,343;
5,017,837; 5,038,081; 5,248,919; 5,399,940; 5,510,679; 5,637,930; 5,909,087; 6,169,377;
6,300,727; 6,380,696; DES 353,798; D496,003 and corresponding foreign patents. U.S. and
foreign patents pending. Lutron, Claro and Maestro IR are registered trademarks and FASS
and Satin Colors are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark
of the National Fire Protection Association, Quincy, Massachusetts.
© 2005 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 11/05 P/N 030-884 Rev. A
IR
®
Installation Instructions for
Single-Location Control
Please Leave for Occupant
Read all instructions completely before
installation.
Important Notes
1.
Caution: To avoid overheating and possible damage to other
equipment, do not use to control receptacles, fluorescent lighting,
motor-operated or transformer-supplied appliances.
2.
Install in accordance with all national and local electrical codes.
3.
When no "grounding means" exist within the wallbox then the NEC
2002, Article 404-9 allows a dimmer without a grounding connection
to be installed as a replacement, as long as a plastic, noncombusti-
ble wallplate is used. For this type of installation, cap or remove the
green ground wire on the dimmer and use an appropriate wallplate
such as Lutron's Claro
or Satin Colors
series wallplates.
®
TM
4.
Do not paint front or back of Maestro IR
Dimmer.
®
5.
Use only to control (1) the primary side of electronic transformer-
supplied low-voltage lighting, (2) incandescent lamps, or (3) a
combination of the two.
6.
This product requires a neutral wire in the wallbox. If a neutral wire
is not present, contact a licensed electrician for installation.
7.
Some fixture manufacturers do not recommend dimming their solid-
state transformers. To determine if a fixture may be dimmed, consult
the fixture manufacturer.
8.
This control is overload protected. If the rated wattage is exceeded,
power to the circuit will shut off until the control cools. If this occurs,
remove excess load from the circuit.
9.
In multi-phase applications, use a separate neutral for each phase
containing a dimmed circuit.
10.
Operate between 0 °C (32 °F) and 40 °C (104 °F).
11.
Dimmer may feel warm to the touch during normal operation.
12.
Recommended wallbox depth is 2 1/2" (63 mm) minimum.
13.
Clean with a soft damp cloth only. Do not use any chemical
cleaners.
Lutron Technical Support Center
For Electronic Low-Voltage and/or
Incandescent Lighting
®
MIRELV-600
Electronic Low-Voltage Dimmer
with IR Receiver
(120 V~ 60 Hz 5–600 W)
MIR-ITFS
Infrared Wireless Transmitter with
One-Touch Button
(3 V
Multigang Installations
When installing more than one control in the same wallbox, it may be
necessary to remove all inner side sections prior to wiring (see below).
Using pliers, bend side sections up and down until they break off.
Repeat for each side section to be removed. Removal of Dimmer side
sections reduces maximum load capacity. Refer to the Dimmer
Capacity Chart below.
®
Breaking Side
Sections
Do Not Remove
Outside Sections
Inside sections are
Side sections are
removed from each
removed from both sides
control
of the middle control
Dimmer Capacity Chart
No sides
1 side
removed
removed
MIRELV-600
600 W max.
500 W max.
1-800-523-9466
0.15 W)
2 sides
removed
400 W max.

Publicidad

loading

Resumen de contenidos para Lutron Maestro IR

  • Página 1 2 sides controls. Please see the seconds until the dimmer LED Lutron will, at its option, repair or replace any unit that is defective in materials or Clean with a soft damp cloth only. Do not use any chemical removed...
  • Página 2 Step 4 Wire the Maestro IR Dimmer. Lutron Technical Support Center 1-800-523-9466 24 hrs / 7 days www.lutron.com Using the wire connectors provided: Connect the ground wire: Single-Location Installation Connect the green ground wire to the green or bare copper ground wire in the wallbox (see Important Note 3).
  • Página 3: Solución De Problemas

    Patentes de E.U.A. y extranjeras pendientes. Lutron y Claro son marcas registradas, y FASS, +1-800-523-9466 (U.S.A., Canadá, y el Caribe) Maestro IR y Satin Colors son marcas registradas de Lutron Electronics Co., Inc. NEC es una Desde otros países llame al: +1-610-282-3800 marca registrada de National Fire Protection Association, Quincy, Massachusetts.
  • Página 4 Paso 4 Cablee el Atenuador Maestro IR. Centro de Soporte Técnico de Lutron +1-800-523-9466 24 horas / 7 días www.lutron.com Usando los conectores de cable ya provistos Conecte el cable de tierra: Instalación de Ubicación Única Conecte el cable de tierra de color verde al cable verde o el cable de tierra de cobre sin aislamiento de la caja de embutir (vea la Nota Importante 3).
  • Página 5 Centre de Support Technique Lutron. Prière de fournir le 6,380,696; DES 353,798; D496,003 et les brevets internationaux correspondants. Brevets en instance aux É.-U. et à l’étranger. Lutron, Claro et Maestro IR sont des marques enregistrées numéro de modèle exact lors de l’appel.
  • Página 6 Etape 4 Préfilez le Gradateur Maestro IR. Centre de Support Technique Lutron +1-800-523-9466 24 hres. / 7 jours www.lutron.com En utilisant les connecteurs fournis, Connectez le fil de mise à la terre : Installation à Emplacement Simple Connectez le fil de mise à la terre vert au fil de terre en cuivre nu ou vert de la boîte murale.

Este manual también es adecuado para:

Mirelv-600Mir-itfs