Lutron Technical Support Center
1-800-523-9466
Single-Location Installation
For installations combining dimmers with other controls in a wallbox, refer to Multigang Installations on page 1
before beginning.
Check off Steps as completed.
Step 1
Turn power off at circuit breaker panel or remove fuse from fusebox.
Step 2
Remove wallplate. Pull switch from wall.
Step 3
Disconnect wires.
Terminal screws:
Turn screw to
loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are
suitable for copper wire only. For aluminum wire, consult an electrician.
Small:
Strip insulation 3/8" (10 mm) for 14 AWG wire
Strip insulation 1/2" (13 mm) for 16 or 18 AWG wire
Use to join one 14 AWG supply wire with one 16 or
18 AWG control wire.
Large:
Strip insulation 1/2" (13 mm) for 10, 12 or 14 AWG wire
Strip insulation 5/8" (16 mm) for 16 or 18 AWG wire
Use to join one or two 12 or 14 AWG supply wires with
one 10, 12, 14, 16, or 18 AWG control wire.
24 hrs / 7 days
www.lutron.com
Backwired:
Insert
screwdriver.
Pull out wire.
Twist wire
connector tight.
Be sure no bare
wire is exposed.
Large
Small
Step 4
Wire the Maestro IR Dimmer.
Using the wire connectors provided:
4a
Connect the ground wire:
Connect the green ground wire to the green or bare copper ground wire in the wallbox (see Important Note 3).
4b
Connect the white wire:
Connect the white wire to neutral.
4c
Connect the yellow wire:
Connect the yellow wire to the wire going to the lighting load.
4d
Connect the black wire:
Connect the black wire to the live wire coming from the distribution panel.
Ground wire
(Bare copper
or green)
Step 5
Mount and align dimmer. Install Claro wallplate.
Align dimmer.
Tighten screws
until snug.
Step 6
Turn power ON.
Electronic
Yellow
Low-Voltage
(and/or
Incandescent)
Load
White
Black
Green
Snap on wallplate.
Slide FASS
switch to
TM
the right.