ENGLISH
GENERAL SPECIFICATIONS
• Operating Altitude: Up to 6562 ft. (2000 m)
• Relative Humidity: <85% non-condensing
• Operating Temperature: 5° to 113°F (-15° to 45°C)
• Storage Temperature: -4° to 140°F (-20° to 60°C)
• Batteries: 2x AAA 1.5V Alkaline
• Dimensions: 5.24" x 1.52" x 1.11" (133 x 39 x 28 mm)
• Weight: 3.1 oz. (90 g) including batteries
• Calibration: Accurate for one year
• Standards: EN61326-1:2013, EN61326-2:2013, EN61010-1:2010,
EN61010-2-030:2010, EN61010-031:2015
Conforms to UL STD. 61010-1, 61010-2-030 and 61010-031.
Certified to CSA STD. C22.2 NO. 61010-1, 61010-2-030
and 61010-031.
5001748
• Pollution degree: 2
• Drop Protection: 9.8 ft. (3 m)
• Ingress Protection: IP41
• Safety Rating: CAT III 250V, Class 2, double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building's low-voltage MAINS installation.
• Electromagnetic Environment: This equipment meets requirements
for use in basic and controlled electromagnetic environments
like residential properties, business premises, and light-industrial
locations.
Specifications subject to change.
ELECTRICAL SPECIFICATIONS
• Voltage Level Indicators:
• AC: 12V, 24V, 120V, 240V
• DC: 1.5V, 9V, 12V, >17V
• DC Polarity Indicators: DC Positive, DC Negative,
both illuminated indicates AC
• Hazardous Voltage Indicator:
• Continuously on when voltage >25V AC or >25V DC
• Blinking at ~2Hz when voltage >240V AC or >60V DC
• AC Frequency: 50Hz / 60Hz
• Input Protection: 250V AC/DC
• Maximum Measurable Voltage: 240V AC (240V AC Indicator)
or 24V DC (>17V DC Indicator)
• Accuracy: Voltage level indicators typically illuminate fully at approx.
70% to 100% of indicated voltage, except for 12V DC (84% to 100%)
and >17V DC (94% to 100% of 17V)
• Auto Power-OFF : After 2 minutes of inactivity
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe injury
or death.
• Before each use verify tester operation by measuring a known voltage.
• Never use the tester on a circuit with voltages that exceed the category
based rating of this tester.
• Do not use the tester during electrical storms or in wet weather.
• Do not use the tester or test leads if they appear to be damaged.
• Keep fingers behind the finger guards and away from the metal probe
contacts when making measurements.
• Use caution when working with voltages above 25V AC RMS or 60V
DC. Such voltages pose a shock hazard.
• Always adhere to local and national safety codes. Use personal
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
• Tester is IP41 dust & water resistant. Following any contact with water,
thoroughly dry tester prior to subsequent use.
CAUTION
• DO NOT attempt to repair this tester. It contains no serviceable parts.
• DO NOT expose tester to extremes in temperature or high humidity.
OPERATING INSTRUCTIONS
TESTING IN CAT III / CAT IV MEASUREMENT LOCATIONS
Ensure the test lead shield is pressed firmly in place. Failure to use the
CATIII / CATIV shield increases arc-flash risk.
0.13" – 0.15" (3.3 mm – 3.9 mm)
TESTING IN CAT II MEASUREMENT LOCATIONS
CAT III / CAT IV shields may be removed for CAT II locations. This will allow
testing on recessed conductors such as standard wall outlets. Take care not
to lose the shields.
0.5" (13 mm)
OPERATING INSTRUCTIONS
Press and hold the On/Off button
for approx. 1 second to turn the tester on or
1
off. When on, the Power/Low Battery indicator
will be continuously illuminated.
2
The tester will automatically power-OFF following 2 minutes of inactivity to conserve
battery life.
Apply test leads
to the system under test to measure voltage. The Voltage
6
Level Indicators
will illuminate indicating the voltage present. When DC
3
voltage is detected, the "+" or "–" polarity indicator
the polarity. When AC voltage is detected, both polarity indicators will illuminate.
DO NOT attempt to measure AC voltages in excess of 240V AC, or DC
voltages in excess of 25V DC under any circumstances. The hazardous
voltage indicator will illuminate in the presence of voltage exceeding
25V AC or DC, with characteristics as detailed in the table below.
HAZARDOUS VOLTAGE
AC VOLTAGE
INDICATOR STATUS
Solid on
>25V AC
Blinking at approx. 2Hz
>240V AC
BATTERY REPLACEMENT
When the Power-ON / Low Battery indicator
blinks, the batteries must be replaced.
2
1. Remove screw
from battery compartment door
8
2. Remove and recycle spent batteries.
3. Install two new AAA batteries. Note proper polarity.
4. Replace battery door and fasten securely with screw.
To avoid risk of electric shock, disconnect leads from any voltage
source before removing battery door.
To avoid risk of electric shock, do not operate tester while battery
door is removed.
CLEANING
Ensure tester is turned off and wipe with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when not in use for a prolonged period of time. Do
not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the General
Specifications section, allow the tester to return to normal operating
conditions before using.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must
be properly disposed of in accordance with local regulations. Please
see www.epa.gov or www.erecycle.org for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069
customerservice@kleintools.com
www.kleintools.com
will illuminate, revealing
4
DC VOLTAGE
>25V DC
>60V DC
.
7
1-877-553-4676
2