Operating Instructions
Series TW5000 Welding Hose Reels
Low Pressure Model Numbers:
TW5400 OLP
TW5425 OLP
TW5400 OLPT
TW5425 OLPT
Dimensions
Four 5/16" diameter mounting holes
SAFETY
Personal injury and/or equipment damage may result if proper safety
precautions are not observed.
• Ensure that reel is properly installed before connecting input and output
hoses.
• Bleed fluid/gas pressure from system before servicing reel.
• Before connecting reel to supply line, ensure that pressure does not
exceed maximum working pressure rating of reel.
• Remember, even low pressure is very dangerous and can cause per-
sonal injury or death.
• Be aware of machinery and personnel in work area.
• If a leak occurs in the hose or reel, remove system pressure immedi-
ately.
IN-SERVICE CAUTION:
• The user is cautioned not to shut off the fuel gas at the regulator or supply source first, as a flashback may result, and thereby damage the
hose.
• Users are cautioned specifically to shut off the gas at the torch first, and then at the regulator or supply source, to limit permeation of gas
through the hose wall. This should be done when the torch will not be used for periods in excess of 30 minutes.
• After the flame has been extinguished and the gas turned off at the supply source, it is recommended that any remaining gas be bled to mini-
mize degradation of the rubber during long shutdowns.
• To prevent an accumulation or concentration of gas that could be explosive or otherwise harmful to personnel, adequate ventillation must be
provided at all times, particularly in confined areas where fuel gas is being used.
• Additional advice for minimizing the permeation problem has been supplied by an NWSA member who states "The source of gas (fuel gas
and oxygen) should be closed before leaving for the day or shift. After the cylinder or manifold valves have been closed, the torch valves
(both fuel gas and oxygen) should be opened to remove all pressure from hoses.
Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725
Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605
Customer Service: 855-634-9109 • reelcraft@reelcraft.com • www.reelcraft.com
A
14 1/2"
B
13 3/4"
C
9 3/4"
Read this manual carefully before installing, operating or
D
2 1/2"
Reels less hose, models TW5000 OLP and
E
6"
TW5000 OLPT, are UL listed #70H2.
• A high tension spring assembly is contained within the reel. Exercise
extreme caution.
• Pull hose from reel by grasping the hose itself, not the control valve.
• Ensure that reel, hose, and equipment being serviced are
properly grounded. Use an ohmmeter to check ground
continuity.
• If reel ceases to unwind or rewind, remove system pressure immedi-
ately. Do not pull or jerk on hose!
• Treat and respect the hose reel as any other piece of machinery,
observing all common safety practices.
IMPORTANT
servicing this equipment.
Form# 834-696B Rev: 7/2013

Publicidad

loading

Resumen de contenidos para Reelcraft TW5000 Serie

  • Página 1 After the cylinder or manifold valves have been closed, the torch valves (both fuel gas and oxygen) should be opened to remove all pressure from hoses. Form# 834-696B Rev: 7/2013 Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725 Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605 Customer Service: 855-634-9109 • reelcraft@reelcraft.com • www.reelcraft.com...
  • Página 2: Installation Instructions

    Check for completeness. output hoses or swivel only. Refer all other repairs to an autho- 2. Configure reel for top, side, or bottom-wind hose dispens- rized service person or directly to Reelcraft Industries, Inc. ing by removing bolts (or nuts) (1) securing guide arm Failure to do so can result in personal injury and/or equipment bracket (2).
  • Página 3 300087 300087 300087 37 90° Ell Oxygen S300091 S300091 S300091 S300091 Hose I.D. and Length None None 1/4” x 25’ 1/4” x 25’ Reel Inlet Connection 1/4” FPT 1/4” FPT 1/4” FPT 1/4” FPT Max. Operating Pressure 200 PSI 200 PSI 200 PSI 200 PSI Max. Operating Temperature 210° F 210° F 210° F 210° F www.reelcraft.com Page 3...
  • Página 4: Series Tw5000 Carretes Dobles Para Soldadura

    Después de haber cerrado las válvulas del cilindro o del múltiple, las válvulas del soplete (tanto la válvula de gas combustible como la válvula de oxígeno) deben abrirse para eliminar toda la presión de las mangueras. Form# 834-696B Rev: 7/2013 Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725 Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605 Customer Service: 855-634-9109 • reelcraft@reelcraft.com • www.reelcraft.com...
  • Página 5 únicamente al reemplazo de las mangueras de entrada/salida o no esté dañado. Hágalo girar manualmente para verificar la rótula. Dirija todas las demás reparaciones a una persona de que su funcionamiento sea suave y sin impedimentos. servicio autorizada, o directamente a Reelcraft Industries, Inc. Verifique que esté completo. Si no lo hace pueden producirse lesiones personales y/o daños 2. Configure el carrete para salida de la manguera enrollada a los equipos, y puede anular la garantía.
  • Página 6: Descripción

    Diámetro interior y longitud de la manguera Ninguno Ninguno 1/4” x 25’ 1/4” x 25’ Conexión de entrada al carrete 1/4” FPT 1/4” FPT 1/4” FPT 1/4” FPT Presión máxima de operación 200 PSI 200 PSI 200 PSI 200 PSI Temperatura máxima de operación 210° F 210° F 210° F 210° F Page 6 www.reelcraft.com...
  • Página 7 • Pour éviter une accumulation ou concentration de gaz qui pourrait être une source d’explosion ou de danger pour le personnel, une ventila- tion adéquate doit être fournie en permanence, en particulier dans les zones confinées où du gaz combustible est utilisé. • Un conseil complémentaire pour minimiser le problème de pénétration a été fourni par un membre de la NWSA : La source de gaz (gaz com- bustible et oxygène) doit être fermée avant de partir en fin de journée ou de quart. Une fois fermés bouteilles ou robinets de distribution, les robinets du chalumeau (gaz combustible et oxygène) doivent être ouverts à nouveau pour évacuer la pression des tuyaux. Form# 834-696B Rev: 7/2013 Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725 Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605 Customer Service: 855-634-9109 • reelcraft@reelcraft.com • www.reelcraft.com...
  • Página 8 Les interventions de l’utilisateur sur le dévidoir sont limitées au remplacement des tuyaux d’entrée ou de sortie, ou du pivot. Confiez toutes les autres réparations à un agent de service agréé, ou directement à Reelcraft Industries, Inc. Sinon vous 1. Déballez et inspectez le dévidoir pour chercher d’éventuels dommages. Faites-le tourner manuellement pour contrôler risquez des blessures corporelles et/ou des dommages sur l’absence de blocage.
  • Página 9 S300091 Diam. interne et longueur de tuyau Aucun Aucun 1/4” x 25’ 1/4” x 25’ Connexion d’entrée de dévidoir 1/4” FPT 1/4” FPT 1/4” FPT 1/4” FPT Pression de service maximum 200 PSI 200 PSI 200 PSI 200 PSI Température de service maximum 210° F 210° F 210° F 210° F www.reelcraft.com Page 9...

Este manual también es adecuado para:

Tw5400 olpTw5425 olpTw5400 olptTw5425 olpt