Descargar Imprimir esta página

Installation Instructions - Reelcraft TW5000 Serie Instrucciones De Operación

Ocultar thumbs Ver también para TW5000 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Series TW5000 Welding Hose Reels

INSTALLATION INSTRUCTIONS

MOUNTING
Caution: Unless reel was specified differently when ordering,
maximum installation height is 16 feet. Do not exceed this dis-
tance. Observe all applicable NEC, OSHA & local codes when
installing this equipment.
2
1
3
1. Unpack and inspect reel for damage. Turn by hand to
check for smooth operation. Check for completeness.
2. Configure reel for top, side, or bottom-wind hose dispens-
ing by removing bolts (or nuts) (1) securing guide arm
bracket (2).
3. Determine new guide arm bracket location and remove
corresponding bolts, (or nuts). Position guide arm bracket
to reel and replace bolts (or nuts).
4. Position reel on floor, wall or ceiling. Secure into place
using four (customer supplied) screws or bolts (3).
INSTALLING THE INPUT HOSES
Caution: Apply teflon tape to all input connections to insure
a proper seal.
Acetylene/fuel gas
inlet 1/4" FPT
(Red)
INSTALLING THE OUTPUT HOSES
Caution: Use extreme caution; reel under tension, avoid
releasing latch mechanism. Apply teflon tape to outlet connec-
tions.
1. Manually turn spool ass'y until spring is tight, back off
Page 2
three turns, then latch.
2. Route output hoses through guide bracket.
3. Using a wrench, firmly hold on to output fittings on swivel
while tightening the hose connector.
SERVICE INSTRUCTIONS
User servicing of the reel is limited to replacing the input/
output hoses or swivel only. Refer all other repairs to an autho-
rized service person or directly to Reelcraft Industries, Inc.
Failure to do so can result in personal injury and/or equipment
damage and may void the warranty.
Caution: Rewind hose on reel, then bleed pressure from sys-
tem before performing the following procedures.
1. Replace hoses in accordance with procedures given in
"Installation Instructions" section of this manual.
REPLACING THE SWIVEL
Caution: Remove supply line pressure before performing the
following procedure.
1. Remove supply line from swivel.
2. Remove swivel assembly from inlet shaft.
3. Apply thread sealant to threaded connection and re-install
swivel assembly to inlet shaft by reversing steps 1 & 2.
ADJUSTMENTS
Oxygen
Caution: Use extreme caution; reel under tension. Avoid
inlet 1/4" FPT
releasing latch mechanism. If necessary, adjust spring tension
(Green)
of reel by adding or removing wraps of hose from spool, one
wrap at a time, until desired tension is obtained. Add wraps
to increase tension. Remove wraps to decrease tension. When
adding wraps of hose, be careful not to exceed the winding
mechanisms spring capacity. Add just enough wraps of hose to
achieve the desired tension. Damage to the winding mechanism
will result if spring is over-tensioned.
www.reelcraft.com

Publicidad

loading

Este manual también es adecuado para:

Tw5400 olpTw5425 olpTw5400 olptTw5425 olpt