Initial programming sequence
Before starting...
To start adjusting the motor limits, make sure that the
setting buttons (red and blue)
unlocked
(fig.
1). The buttons are unlocked when they "click"
once pressed.
Once both buttons are unlocked, you can start adjusting the
motor limits. If both buttons or at least one is locked, follow the
procedure on page 5 to reset the motor to factory default
settings before proceeding with the limit setting.
Make sure that the panels are approximately in the middle of
the track. To do this, remove the track
side of the motor, remove the GEAR, and pull the drive
until the panels are in the middle of the track. Then place the
GEAR
back
(fig.
2).
To adjust the limits it is necessary to use the VTi
Receiver & Transformer Wall Switch (6-700-AT-AC227).
Make sure it is properly wired and installed
100-240 V AC
Input Voltage
WALL CONTROL
(6 700 AT AC227)
FRONT
STOP BUTTON
vertilux.com
2
© 2018. Vertilux, Ltd. All Rights Reserved. Last revised: October 2018.
located on the motor head are
COVER
located on the
Celtic Radio
®
(fig.
3).
L: Line
E: Ground
N: Neutral
100-240 V AC
DIRECTION
BUTTONS
VTi
CELTIC MOTOR
®
6-710-SP-00XXX
SN: 324385 U = 24V DC
n= 59 U/mim
Fig.
3. Wiring Connection Scheme
2 limit
Fig.1. Limit setting buttons
CHAIN
CHAIN
24 V DC
Output Voltage
0,009 kW
GEAR
COVER
Fig.
2. Motor side
WALL CONTROL