EN
INDEX
1 Introduction to the instructions, and warnings 4
2 Product description
3 Technical specifications
4 Installation
5 Testing
6 Maintenance
7 Disposal
8 Illustrations and figures
1
Introduction to the instructions, and
warnings
This manual is for use solely by technical personnel
who are qualified to carry out the installation.
No information in this document is of interest to
the end user.
This manual refers to the AG/ALED lights for the
arm of the ROGER AGILIK barrier and must not be
used for other devices.
DANGER OF
WARNING
ELECTROCUTION
Read the instructions carefully before installation.
To avoid physical risk, before working with the
device, always disconnect the electricity from the
AG/CTRL control unit.
The installation must be performed only by qualified
technical personnel according to the standards in
force.
Make the connections with cables suitable to the
required voltages, respecting the product's technical
specifications.
3
Technical specification
SUPPLY VOLTAGE
MAXIMUM INPUT VOLTAGE
OPERATING TEMPERATURE
DEGREE OF PROTECTION
PRODUCT DIMENSIONS
4
Page
WARNING! The LEDs are sensitive to electrostatic
discharges so avoid touching the conductors with
your fingers.
4
4
Always handle the LED strip with caution, do not
5
twist, pull, do not step on, do not bend or puncture
5
the cover.
5
5
2
Product description
14
The lights for the arm of the ROGER AGILIK barrier
make the arm more visible in all conditions. They
are made up of a LED strip that is inserted along
both sides of the arm.
By configuring the command unit they are connected
to, it is possible to configure the start-up procedure
(parameter
They are supplied in 3 sizes:
• for 3m arms: AG/ALED6C
• for 4m arms: AG/ALED8C
• for 6m arms: AG/ALED12C
24Vdc ± 10%
AG/ALED6C
5W
AG/ALED8C
7W
AG/ALED12C
10W
-20°C ... +55°C
IP54
AG/ALED6C
size in mm. 15x6x7000 Weight: 0,26Kg
AG/ALED8C
size in mm. 15x6x9000 Weight: 0,34Kg
AG/ALED12C
size in mm. 15x6x13000 Weight: 0,49Kg
79
).