General precautions
Important safety instructions: READ CAREFULLY!
•
Installation, programming, commissioning and maintenance must only be carried out by expert qualified technicians in full
•
compliance with the regulations in force.
Wear anti-static shoes and clothing if working on the electronic circuit board.
•
Keep this precaution information.
•
Disconnect the power supply during any cleaning or maintenance work.
•
The product must only be used for the purpose for which it was expressly designed. Any other use is to be considered
•
dangerous.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
•
A
1
M1
BOUT
Functions
A
Terminal board 1
BOUT Busbar
+
16-18 VDC power supply
–
Terminal board 2
–
Earth
Door release button (NA)
Solenoid lock
12 V - 1 A max
–
5
4
PROG
3
2
M2
SW3
F
PROG key 3 and PROG LED 4
Programming key and LED (see 'Programming' para-
graph). The PROG LED can be in the following condi-
tions:
Off
On
Flashing slowly
Flashing quickly
Adjustments 5
Speaker audio
microphone audio
solenoid lock 1÷10 s. (default 1 s)
JUMPER
6 SW3: Enabling/disabling intercom function (see
'Programming' paragraph).
Technical features
Type
Power supply (VDC)
Consumption (mA max)
Consumption in stand-by mode
(mA)
Dimensions (mm)
Storage temperature (°C)
Operating temperature (°C)
IP Rating
Video standard
Resolution (pixel)
Minimum lighting (LUX)
LIVIPR
16÷18
250
100
99x207x30
-25/+70
-15/+50
54
PAL/NTSC
680x12
1