FORK REBOUND SETTING
The rebound adjuster controls the rate of speed at which the fork
extends after compressing. The rebound setting is dependent on
the air pressure setting. For example, higher air pressures require
slower rebound settings. You will use your air pressure to find your
rebound setting.
Turn the rebound adjuster to the closed position (full clockwise)
until it stops. Then back it out (counter-clockwise) to the number
of clicks shown in the table below.
OPEN
(COUNTER-CLOCKWISE)
LEAST AMOUNT OF
REBOUND DAMPING;
SHOCK REBOUNDS
FASTEST
32 Live
Pressure
(psi)
65-74
80-90
96-106
REBOUND
ADJUSTER
111-126
17
15
13
11
34 Live
Pressure
(psi)
58-68
72-82
86-96
100-114
9
7
5
3
1
8
36 Live
Recommended
Pressure
Rebound
(psi)
Setting
55-63
17-15
67-76
14-11
80-89
10-8
93-106
7-3
CLOSED
(CLOCKWISE)
MOST AMOUNT OF
REBOUND DAMPING;
SHOCK REBOUNDS
SLOWEST