Bathroom
Exhaust Fan
MODEL: 8814R
SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to
the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or
shower.
WARNING: To reduce the risk of fire or electric shock, do not
use this fan with any solid-state speed control.
• Not for use in kitchens.
• Suitable for use over tub or shower when installed in a GFI
(or GFCI) Protected Branch Circuit.
• The exhaust fan consists of the housing, power unit/blower
assembly (motor, wheel, mounting plate,) grille and duct collar.
• Do not install in a ceiling insulated to a value greater than R-40.
®
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
HOUSING
SLOTS
TABS
FOR BEST RESULTS
When installing the exhaust fan in a new construction site,
install housing during the rough-in construction of the building.
The blower unit and grille should be installed after the finished
ceiling is in place.
To install the exhaust fan in an existing finished building
requires an accessible area (attic or crawl space) above the
planned location.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4" round duct.
2. Plan to run duct from discharge opening of fan to the outside.
For best fan performance, make duct run as short as possible.
3. Use optional NuTone ducting accessories as needed. Refer to
your NuTone catalog for a complete listing of available
accessories.
WIRING
Plan to run 120vAC house wiring (with ground) from power
source, through a standard wall switch to junction box in fan
housing.
DUCT
COLLAR
POWER UNIT/
BLOWER
ASSEMBLY
GRILLE
FIGURE 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone 8814R

  • Página 1 For best fan performance, make duct run as short as possible. 3. Use optional NuTone ducting accessories as needed. Refer to WARNING: To reduce the risk of fire or electric shock, do not your NuTone catalog for a complete listing of available use this fan with any solid-state speed control.
  • Página 2 STANDARD WALL SWITCH white; black to black. Connect green or bare ground wire (NOT INCLUDED) OR SWITCH to green ground lead. OPTIONAL NUTONE SPEED CONTROL POWER/BLOWER UNIT INSTALLATION 1. Place power/blower unit into housing so that mounting 120vAC, 60 Hz plate's tabs insert into slots in housing.
  • Página 3 WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.
  • Página 4: Importantes Directives De Sécurité

    Pas pour une utilisation dans les cuisines. l'interrupteur mural. Pour une commande séparée du ventilateur et • Prévu U.L. pour utilisation dans une cabine de douche ou de salle de l'éclairage, utiliser un interrupteur NuTone en option. de bain lorsque la dérivation est protégée avec GFCI.
  • Página 5: Installation Dans Une Construction Neuve

    D’INTERRUPTEUR COMMANDE DE VITESSE à l'emplacement du ventilateur. Voir Figure 4. NUTONE EN OPTION 2. Placer un raccord agréé dans le trou d'entrée du câblage. 3. Tirer les câbles par le raccord jusque dans le boîtier de raccordement. Serrer le raccord.
  • Página 6: Installation Du Moteur

    MARCHANDIBILITÉ OU D'ADAPTATION À UN USAGE PARTICULIER. Pendant cette période d’un an, NuTone procédera au remplacement ou à la réparation sans aucuns frais, mais à sa propre discrétion, de tout produit ou pièce jugé défectueux dans le cadre d'une utilisation normale. CETTE GARANTIE NE VISE PAS LES DISPOSITIFS D'AMORÇAGE NI LES TUBES DES LUMINAIRES FLUORESCENTS. Cette garantie ne couvre pas (a) l'entretien et le service courants ni (b) les produits et les pièces ayant fait l'objet d'un usage abusif, de négligence, d'un accident, d'un entretien ou d'une réparation non...
  • Página 7: Ventilador Aspirante Para Cuartos De Baño

    3. Use accesorios de tubería opcionales NuTone si fuera ADVERTENCIA: Para reducir el riesgo de incendio o choque eléctrico, no utilice este ventilador con ningún dispositivo con control de necesario. Vea su catálogo de NuTone para una lista completa la velocidad de estado sólido. de accesorios disponibles.
  • Página 8: Instalacion En Un Nuevo Edificio En Construccion

    DE VELOCIDADES 1. Corra alambres de 120v c.a. (incluyendo a tierra) desde el interruptor OPCIONAL DE NUTONE de pared hasta donde se encuentra el ventilador. 2. Corra el alambre a través del agujero de acceso y hacia adentro de la caja de conexiones.
  • Página 9: Instalacion De La Unidad De Poder/Soplador

    NO LIMITADAS A, GARANTÍAS NO EXPRESADAS DE MERCANTIBILIDAD O ADAPTABLES A UN PROPÓSITO EN PARTICULAR. Durante este período de un año, NuTone reparará o reemplazará a su opción y sin costo, cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio.
  • Página 10: Parts List

    DUCT ADAPTER ASSEMBLY 30652-000 44208 GRILLE & SPRING ASSEMBLY 44208-000 10034 RECEPTACLE 10034-000 NuTone Attn: Parts Department ® NOTE: Always order by 4820 Red Bank Rd. current part number Cincinnati, OH 45227-1599 Phone: (513) 527-5426 8814R I.I. Fax: (513) 527-5173...

Tabla de contenido