3.1 Thermostatic Cartridge
-
Shut off the stop valves.
-
Removed the handle and temperature stop cam.
-
Unscrew the cartridge (picture 3.1).
-
Put the cartridge into vinegar or into decalcifying solution for one night.
-
Clean the inner part of the body with a wet cloth (picture 3.2).
-
Lubricate the gaskets of the cartridge with special or alimentary grease.
-
Replace the cartridge in its place.
-
Temporary put the handle on the cartridge.
-
Keep the water coming out of the mixer for at least 1 minute, check the temperature
with a thermometer, until you reach the temperature of 38ºC.
-
Remove the handle avoiding any rotation.
-
Put on the plastic cam with the red dot turned to the top.
-
Important: the thermostatic mixer doesn't work properly without the plastic cam.
Without the plastic cam the temperature stop at 38º doesn't work.
-
Replace the handle definitively with 38ºC mark accordingly to the red dot of the cam.
-
We recommend make the thermostatic cartridge maintenance once per year. In
places of hard water we recommend the cartridge maintenance twice per year.
3.2 Filtros / Filters
-
Cerrar la llave de paso
-
Quitar los filtros (llave 30)
-
Quitar los filtros y limpiarlos con agua.
-
En caso que haya depósitos de cal, dejarlos dentro del agua con vinagre o una
solución antical durante 12 horas.
-
Poner los filtros dentro otra vez en las tuercas e instalar otra vez el termostato
-
Shut off the stop valves.
-
Remove the filters from the pipes (Key 30)
-
Remove the filters from their seats and wash them with water.
-
In case of lime-scale deposit, leave them into water, into vinegar or into lime-scale
solution for 12 hours.
-
Replace filters into the nuts and install again the thermostatic mixer.