INSTALL WATER LINE CLAMP
4
• Attach the metal water line clamp (strain relief) (6)
to the refrigerator. Drive the screw (5) from the kit
through the clamp (6) at the small indent into the
back of the cabinet.
• The metal clamp is for the house water line (see the
Water Line Installation Instructions). It is not to be
used for the water tube from the water valve up to
the inlet.
5
Small indent for water
line clamp installation
ROUTE AND ATTACH
5
THE WATER TUBE
Fasten the plastic water tube to the back
•
of the refrigerator with adhesive-backed
fasteners (4), spacing the fasteners as shown
to take up slack in the tube.
Installation Instructions
6
Adhesive-backed
fasteners for water tube
15
WATER VALVE INSTALLED
6
Refer to the Water Line Installation Instructions for
connection to the home water supply. After water
line installation is completed, set the icemaker
power switch to ON.
The icemaking cycle will not begin until the
icemaker and freezer compartment reach
operating temperature, then icemaking will begin
automatically.
REINSTALL THE COVER
7
Reinstall the compressor compartment access
cover. This requires using the screws you removed
previously to reattach the cover to the back of the
refrigerator case. This must be reinstalled for your
refrigerator to function properly.